    • Takach, J. (Energy Systems Laboratory (http://esl.tamu.edu), 1985-05)
      The Truck Receiving Dock 66 at the General Motors Fisher Body Division Plant in Euclid, Ohio had always been a source of constant employee complaints during the heating season. Despite management's efforts to maintain as ...
    • Nelson, R. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      The low cost of steam combined with the maintenance free operation of steam ejectors has assured their unquestioned use in providing the necessary vacuum for crude distillation vacuum towers. However, the cost of steam ...
    • Muller, C. (Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
      More than 40 percent of Europe's primary energy is required for conditioning of buildings. By improving energy efficiency, approximately 30 percent of this energy could be saved. Energy counts for 35 percent of the operating ...
    • Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit (2010-03)
      This report provides detailed information about the potential savings from the 2012 Federal Legislation to phase out incandescent lamps and the NOx emissions reduction from the replacement of incandescent bulbs with Compact ...
    • Kim, H.; Baltazar, J.C.; Haberl, J.; Lewis, C.; Yazdani, B. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)
    • Sylvester, K. E.; Haberl, J. S.; Song, S.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      U.S. businesses and institutions spend an estimated $175 billion per year for energy. Of that, the fraction under performance contracts and energy service agreements is currently growing, aided by cheaper monitoring ...
    • Cheng, W. S.; Zhi, C. S. (Energy Systems Laboratory (http://esl.tamu.edu), 1985-05)
      The recovery and utilization of condensate has a remarkable energy saving effect if the following are properly done: 1) Determination of a correct and reasonable recovery plan; 2) Selection of bleed valve with good ...
    • Taborek, J. J.; Klein, D. E.; Fair, J. R. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
      The use of segmental baffling in shell-and-tube heat exchangers has become standard design practice, and process heat transfer specialists recognize that such baffling is the basis for most design procedures. Data from ...
    • Cook, T. H. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1980)
      With the Oil Crisis of 1972-1973, the attitude by Industry on fuel usage and conservation began an evolutionary change in attitudes. This change in attitudes was brought about by three strong motivators for conservation: ...
    • Lingousky, J. E.; McKay, J. R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1983)
      In 1982, 6.9 million BOE of energy costing nearly $600 million was used in approximately 16,000 Bell System Telephone equipment buildings. About 27% of that energy was used for heating, ventilating and air conditioning. ...
    • Fisher, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)
      Current design improvements of both the rotating and stationary aerodynamic components of centrifugal compressors can greatly increase the efficiency of vintage machines. A centrifugal compressor built in the 1970's or ...
    • Pouilliart, R.; Van Hecke, F. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1981)
      An exergy analysis of carbonate solution C02 removal systems which use solution flashing shows that there is no energy saving by using a mechanical thermocompressor instead of a steam-jet ejector. In a 1000 ShT/D ammonia ...
    • English, M. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
    • Barrer, P. J.; Jones, S. M. (Energy Systems Laboratory (http://esl.tamu.edu), 1998-04)
      This paper presents case studies of two moderately sized ammonia refrigeration systems retrofitted for floating head pressure control. It also presents a parametric analysis to assist in selecting appropriate pressures in ...
    • Spain, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      The purpose of the research study was to determine if building loads could be reduced by using an intelligent controller rather than a thermostatic controller to operate heating and air conditioning equipment. In order to ...
    • Simonetti, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      Water evaporates spontaneously in contact with the air, absorbing around 680 W/(kg/h of evaporated water) from the air (1,053 BTU/lb.). Direct Evaporative Cooling (DEC) exploits this simple physical phenomenon to achieve ...
    • Lubbeck, W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      Arc furnace melting which at one time was almost exclusively used to produce alloy steel and steel castings is now widely accepted in the industry as an efficient process to produce all types of steel and iron. Presently, ...
    • Turney, R. L.; Young, F. J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      Food processors have the unique responsibility of maintaining environmental, process and sanitation standards for government and consumers. Usually the food plant is a large facility with many sources of contamination, all ...
    • Zhou, A.; Tutterow, V.; Harris, J. (Energy Systems Laboratory (http://esl.tamu.edu), 2009-05)
      The industrial sector accounts for more than one-third of total energy use in the United States and emits 28.7 percent of the country’s greenhouse gases. Energy use in the industrial sector is largely for steam and process ...
    • Fishel, F. D. (Energy Systems Laboratory (http://esl.tamu.edu), 1979)
      This paper investigates the energy savings available by utilizing variable speed motors on pump and fan applications. Conventional control of flow or pressure in process plants is normally accomplished by throttling the ...