    • Murphy, W. E.; Turner, W. D.; O'Neal, D. L.; Seshan, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      In late 1983, a cost containment program was initiated out of the governor's office directed at the major state agencies. The Energy Management Group at Texas A&M University provided technical expertise in obtaining agency ...
    • Clark, W. H. II (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
      The task of the lighting designer has become very complex, involving thousands of choices for fixture types and hundreds of possible lamps. The designer who can consider the most combinations of these items guarantees each ...
    • Keazer, J. A.; Nutter, D. W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
    • Burke, T. E.; Heffington, W. M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1989)
      In 1984 and 1986, 35.3 million square feet of state owned buildings were audited to identify cost saving retrofit projects. Originally intended for direct legislative funding or bond sales, funding became available in 1989 ...
    • Kiec, T. M. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
      New technology has developed video equipment capable of inspecting interior lined and unlined ductwork. Where IAQ (Indoor Air Quality) questions require inspections of suspicious air conveyance systems. Video recordings ...
    • Soebarto, V.; Reddy, A.; Bou-Saada, T. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      This paper describes a project where selected energy conservation measures in two Habitat for Humanity houses in Houston, Texas were measured using side-by- side measurements of identical houses and calibrated simulation. ...
    • Saman, N.; Heneghan, T.; Bou-Saada, T. E. (Texas A&M University (http://www.tamu.edu); Energy Systems Laboratory (http://esl.tamu.edu), 1996)
      This study investigates the feasibility of using direct and indirect evaporative cooling systems for correctional facilities in two different Texas climatic regions with the DOE-2.1E hourly energy simulation program. ...
    • Liu, M.; Zhu, Y.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      In most chiller and boiler central plants, the energy management and control systems (EMCS) monitor and record key operation parameters and energy production continuously. A method was developed to identify potential O&M ...
    • Devine, K. D.; Mazzucchi, R. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1989)
      This paper details how the U.S. Department of Energy, Federal Energy Management Program (FEMP) is applying metering technology to conduct empirically based analyses o f energy use by federal agencies. Continuing developments ...
    • Crowley, G. D.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      This paper discusses the use of an independent network of remote weather stations for building energy analysis to assist agencies participating in the Texas LoanSTAR Monitoring and Analysis Program. A review of the sensors ...
    • Simmonds, P.; Gaw, W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      In order to conserve energy and create a comfortable climate for both passengers and workers at a new large international airport in Thailand, a design concept was created where only the first 2m above the occupied zone ...
    • Dean, B.; Gamble, D.; Kaiser, D.; Meisegeier, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
    • Haasl, T.; Wilkinson, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      Using the commissioning process, states are beginning to improve and optimize their existing building stock as well as ensure that their new construction projects perform according to design. This paper reports on the ...
    • Brightbill, E. L.; Rutt, J. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      Traditionally, energy monitoring and control systems (EMCS) have been used, as the name implies, to monitor and control heating, ventilating and air conditioning systems, however, this paper will identify other benefits ...
    • Stum, K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      The power and flexibility in building energy management systems (EMS) provide building operators, system consultants and technicians with a useful tool for assessing building equipment and system operation. This paper ...
    • Culp, C.; Mills, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      Mentor is an expert system which was developed and introduced in 1986 assists service refrigeration techs to perform the correct preventative maintenance (PM) and diagnostics on centrifugal chillers at the right time. This ...
    • Chen, Q.; Xu, C.; Deng, S.; Claridge, D. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      The capital investment for the distribution system is often the most expensive portion of a district heating and cooling system, which usually constitutes 50 to 70% of the total cost. Because of high initial cost, it is very ...
    • Phillips, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      A new tool, the INTERNET, has arrived on the scene to help everyone who has anything to do with energy: the energy user, the utilities, the equipment manufacturers, energy management firms, and energy brokers. The INTERNET ...
    • Horn, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      One of the first steps in setting up an energy management program in a commercial building is determining operating costs per energy consuming system through a utility cost analysis. This paper illustrates utility cost analysis ...
    • Verdict, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
      Texas A&M University main campus in College Station consists of 114 buildings served by two central plants. The two main campus loops are more than 50 years old with a total piping length for each loop in excess of 13 ...