    • Song, L.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      Both analytical and the numerical methods have been developed to compares the energy performance of the OAHU systems and the two-AHU (TAHU) system. The OAHU system saves up to 1.85 kilojoules heating energy for each kilogram ...
    • Tackett, R. K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1989)
      Ice storage offers many opportunities to use other tcchnologies, such as heat recovery and cold-air distribution. In fact, by using them, the designer can improve the efficiency and lower the construction cost of an ice ...
    • Kimball, M. A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      The Lone Star Gas Corporate headquarters, in Dallas, Texas, consists of a five building, 355,000 square foot office complex with buildings ranging in age from 14 - 60 years old between 20,000 - 100,000 square feet (SF), ...
    • Zhou, Q.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      An on-line self-tuning algorithm of PI controller for the heating and cooling coil in buildings is described in the paper. The algorithm evaluates the controller performance by the integral square error (ISE) of the coil ...
    • Sieber, R. E.; Dahmus, A. B. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      Thermal storage systems offer utilities a means to change the energy use patterns of both residential and commercial and industrial (C&I) customers by moving water-heating and space-conditioning loads from peak to offpeak ...
    • Downing, C.; Bayer, C. W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      The results of numerous Indoor Air Quality (IAQ) building investigations conducted by the Georgia Tech Research Institute have shown that building Operation and Maintenance (O&M) is a very common source of IAQ problems. ...
    • Phillips, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      Absorption refrigeration systems are one of the oldest systems available. The fundamentals of absorption refrigeration were formulated about 1777, and the first successful absorption machine was developed in 1850. The first ...
    • Withers, C. R. Jr.; Cummings, J. B. (Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
      Wind washing is a general term referring to diminished thermal control caused by air movement over or through a thermal barrier. The primary focus of this paper is towards a specific type of wind washing where wind can ...
    • Cui, Y.; Liu, M.; Conger, K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      An optimal airflow control method and procedure have been developed for laboratory air handing unit (LAHU) systems using linear optimization theories. The optimal airflow control minimizes the thermal energy consumption ...
    • Joo, I. S.; Song, L.; Liu, M.; Douglas, B. (Energy Systems Laboratory, 2008-12)
      A multi-zone air-handling unit was popular several decades ago due to the convenience of small sized modular units, which were inexpensive to install and easily maintained in a mechanical room. The cost and convenience ...
    • Knebel, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      Thermal storage is becoming a standard consideration in HVAC and process cooling systems. As the technology is refined, more attention is being given to minimize the energy consumption and power demand requirements. This ...
    • Thompson, C. T.; Beach, W. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      Over the past twelve years, Texas Instruments has developed extensive energy management programs that have enabled them to reduce energy usage by 42%. Typically, these reductions have been a result of the application of ...
    • Fiorino, D. P.; Priest, J. W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      A model was developed to find a viable solution to the problem of selecting the optimal sequence of refrigeration equipment (chillers, cooling towers, pumps) to operate in a Central Utility Plant. The optimal equipment ...
    • Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain ...
    • Giebler, T.; Wei, G.; Deng, S.; Claridge, D. E.; Turner, W. D.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Reducing unnecessary building energy costs is becoming more of a priority. Rising fuel prices and a global emphasis on energy efficiency are key contributing factors. This push towards energy efficiency certainly applies to ...
    • Gidwani, B. N. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      Chilled water systems are one of the major energy consumers in industrial, commercial, and institutional complexes. The centralization of chilled water systems has considerable advantages, namely: simplified controls, the ...
    • Wang, G.; Cui, Y.; Yuill, D.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      Both analytical and numerical optimization methods have been developed to optimize multi-stack exhaust systems for application in new system designs. In these systems the combined airflow capacity of the stacks equals the ...
    • Wei, G.; Claridge, D. E.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The supply air temperature for a single-duct variable air volume (VAV) system is usually set as a constant. To minimize the simultaneous cooling and heating, this supply temperature is often reset based on either return ...
    • Shami, U. F. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      Air side economizer cycle is a control scheme that is often used in WAC systems to reduce cooling energy consumption by introducing variable quantities of ambient air into a conditioned space to satisfy the space cooling ...
    • McGinley, W. M.; Jones, A.; Turner, C.; Chandra, S.; Beal, D.; Parker, D. S.; Moyer, N.; McIlvaine, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      In partnership with the Florida Solar Energy Center (FSEC), two manufactured homes were located on North Carolina A&T State University's campus in Greensboro, NC and used in a side-by-side energy consumption comparison. ...