Analysis of Energy Conservation Options for USDOE Child Development Center, Final Summary Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
The U.S.D.O.E. Forrestal Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features such as efficient lighting, a photovoltaic system, an energy ...
Texas LoanSTAR Monitoring and Analysis Program—Monitoring and Advisory and Review Committee (January 1991)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Use of Calibrated Simulation for the Evaluation of Residential Energy Conservation Options of Two Habitat for Humanity Houses in Houston, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
This paper describes a project where selected energy
conservation measures in two Habitat for Humanity
houses in Houston, Texas were measured using side-by-
side measurements of identical houses and
calibrated simulation. ...
DOE-2 Simulations for Cuero and Karnes County Prison Sites: Draft Progress Report
(Energy Systems Laboratory (http://esl.tamu.edu), 1995-12)
The intent of this project was to model each of the large buildings at the Karnes County 2,250 bed and Cuero 1,000 bed prison sites with the DOE-2 building energy simulation program and to deliver a working model to the ...
Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
This report presents the measured degradation in performance of a residential air conditioning
system operating under degraded conditions. Experiments were conducted using a R-22 threeton
split-type cooling system with ...
Texas LoanSTAR Monitoring and Analysis Program: Report to the Monitoring and Analysis Review Committee
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
Texas LoanSTAR Monitoring and Analysis Program: Report to the Monitoring and Analysis Review Committee, August 1991 (Volume I)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
The LoanSTAR program has now completed its second prototype year. This report is Volume I of a two volume set that documents the progress since the January 1991 MARC meeting. This first voume contains photocopies of the ...
LoanSTAR Monitoring and Analysis Program Building Energy Monitoring Workbook Submitted to the Texas Governor’s Energy Office by the Improved Energy Audit Process Task (Aug. 1992)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
This building energy monitoring workbook has been prepared for the Texas Governor's
Energy Office by the Improved Energy Audit Task of the LoanSTAR Monitoring and
Analysis Program. This workbook is intended to be a ...
Potential Operation and Maintenance (O&M) Savings in the John Sealy South Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
The LoanSTAR Monitoring and Analysis Group was requested by UTMB to investigate O&M measures in their five LoanSTAR program buildings. This report describes the suggested O&M measures in John Sealy South Building, an ...
Estimated Savings from Turning Off Unnecessary Lights at the Langford Architecture Center During the 1996 Christmas Holidays
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1997)
During the 1996 Christmas holidays the College of Architecture initiated a trial program to turn off unnecessary lights during unoccupied periods. This effort targeted the unnecessary lights in all studios, classrooms, ...