LoanSTAR Monitoring and Analysis Program: Presentation Summary of the State Capitol Complex Building Operation and Maintenance Field Test
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
During the Fall of 1992 a comprehensive survey was conducted on
eight buildings at the State Capitol Complex to determine potential
operations and maintenance (O&M) savings opportunities. A verbal
report of the findings ...
Potential Operation and Maintenance (O&M) Savings in the Basic Science Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential energy savings due to optimizing the Heating, Ventilation and Air Conditioning (HVAC) operation schedule in the Basic Science Building at University of Texas ...
Status of Revisions to ASHRAE Standard 62
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
The American Society of Heating Refrigerating
and Air Conditioning Engineers (ASHRAE) Standard
62- 1989 "Ventilation for Acceptable Indoor air
Quality", adopted in 1989, is widely used by HVAC
engineers to determine ...
Calibrating DOE-2 to Weather and Non-Weather-Dependent Loads for a Commercial Building: Data Processing Routines to Calibrate a DOE-2 Model, Volume II
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
DOE-2 yields hourly data on specific variables provided the user specifies the
HOURLY-REPORT instruction. Analyzing the simulation results with hourly data gives a more
detailed picture of how well the model is predicting ...
Summary of UTMB O&M Project: Energy Conservation Potential in Five Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report is a summary of five reports (references 1 to 5) which provided detailed
descriptions of an O&M investigation of the following five buildings on the UTMB
campus: 1) John Sealy North Building(JSN); 2) Clinical ...
Data Polling Routine (PlotHood) to Generate Weekly Inspection Plots for Fort Hood, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1996)
This report has been prepared for the United States Army Construction Engineering Research Laboratories (CERL) located at Champaign, IL. The report describes the work performed by the Energy Systems Laboratory (ESL) of ...
Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at Texas A&M University -- Galveston (TAMU-G) Galveston, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
The physical plant director and staff at Texas A&M University at Galveston (TAMU-G) do a very good job of maintaining TAMU-G facilities and keeping expenses down. During our visit, however, we were able to identify several ...
A Report on the Environmental Impact of the Texas LoanSTAR Program from May 1989 to September 1995
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1995)
The Texas LoanSTAR (Loans to Save Taxes and Resources) program was created by the state of Texas in 1989 to lend money for energy conserving improvements, or retrofits, in public buildings. As of September 1995 the LoanSTAR ...
Vibration Monitoring Of Turbomachinery.
(Texas A&M University. Turbomachinery Laboratories, 1990)
The overall concept of vibration monitoring is presented based upon theory and the practical constraints of machinery construction, transducer characteristics and the cost/benefit ratio of available systems. General features ...
Gas Turbine Control Systems Incorporating Condition Monitoring And Fault Tolerance.
(Texas A&M University. Turbomachinery Laboratories, 1990)
Novel concepts in gas turbine control technology incorporating condition monitoring and fault tolerance are described. Concerns with fault tolerance, system reliability, and users functionalities are discussed. The importance ...