Search
Now showing items 1-10 of 145
A Simplified Procedure for Sizing Vertical Ground Coupled Heat Pump Heat Exchangers for Residences in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
A simplified technique for the sizing of vertical
U-tube ground coupled heat pump (GCHP) heat
exchangers for Texas climates was developed
utilizing a transient simulation model of a ground
coupled heat pump and weather and ...
Cooling-Only Prism Analysis of Eleven College Station Homes and Interpretation of Building Physical Parameters
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
A cooling-only PRISM analysis has been
performed on eleven new residences in College
Station using electricity billing data over an entire
year. This study revealed that, provided one corrects
for effects such as vacation ...
Effect of Radiant Barrier Technology on Summer Attic Heat Load in South Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
The objective of the study was to experimentally
evaluate the performance of radiant barriers in
single-family occupied housing units in South
Texas. Ceiling heat fluxes, attic air temperatures,
indoor air temperatures, ...
Dehumidification Without Re-heat Using Face and Bypass Dampers
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Installations with chill water cooling, needing
constant air volume and dehumidification,
traditionally use a draw through air handling unit
with a cooling coil and a re-heat coil.
Dehumidification is achieved by overcooling ...
Residential Air Conditioner Direct Load Control "Energy Partners Program"
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Demand side management
programs like Energy Partners
can provide an effective peak
reducing capability which
within a carefully designed
integrated resource plan can
help to ensure that the
system's load requirements are
met ...
Designing a Thermal Energy Storage Program for Electric Utilities
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Electric utilities are looking at thermal
energy storage technology as a viable demand side
management (DSM) option. In order for this
DSM measure to be effective, it must be
incorporated into a workable, well-structured
utility ...
Energy Savings in Food Processing Dehumidification
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Food processors have the unique
responsibility of maintaining environmental,
process and sanitation standards for government
and consumers. Usually the food plant
is a large facility with many sources of
contamination, all ...
A Successful Cool Storage Rate
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Houston Lighting & Power
(HL&P) initiated design and
development of its commercial
cool storage program as part
of an integrated resource
planning process with a
targeted 225 MW of demand
reduction through DSM.
Houston's ...
Feasibility of Municipal Water Mains as Heat Sink for Residential Air-Conditioning
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
It has been proposed that municipal
water mains be used as the heat sink or the heat
source for air-conditioning or heating,
respectively. This paper addresses the extent of
thermal contamination associated with the use
of ...
Load Management DSM: Past, Present & Future
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Load Management has grown in acceptance
over the past several decades as a reliable
means to provide a demand-side resource of
demand capacity. This paper first reviews
the significant break-throughs of load
management ...