Now showing items 11-20 of 156
Energy Efficiency / Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Vol. II – Technical ReportAnnual Report to the Texas Commission on Environmental Quality, Sept. 2003 to Aug. 2004
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)
The Energy Systems Laboratory, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, submits its third annual report, Energy Efficiency/Renewable Energy (EE/RE) ...
Energy Savings Assessment for the Robert E. Johnson State Office Building in Austin, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
U.S. businesses and institutions spend an
estimated $175 billion per year for energy. Of that, the
fraction under performance contracts and energy
service agreements is currently growing, aided by
cheaper monitoring ...
Energy Efficiency / Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Vol. I – Summary ReportAnnual Report to the Texas Commission on Environmental Quality, Sept. 2003 to Aug. 2004
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)
The Energy Systems Laboratory, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, submits its third annual report, Energy Efficiency/Renewable Energy (EE/RE) ...
NOx Emissions Reductions from Implementation of the 2000 IECC/IRC Conservation Code to Residential Construction in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
Four areas in Texas have been designated by
the United States Environmental Protection
Agency (EPA) as non-attainment areas because
ozone levels exceed the National Ambient Air
Quality Standard (NAAQS) maximum allowable
limits. ...
Methodology to Calculate NOx Emissions Reductions from the Implementation of the 2000 IECC/IRC Conservation Code in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
Four areas in Texas have been designated
by the United States Environmental Protection
Agency (EPA) as non-attainment areas because
ozone levels exceed the National Ambient Air
Quality Standard (NAAQS) maximum allowable
limits. ...
NOx Emissions Reduction from Continuous Commissioning(R) Measures for the Dallas-Fort Worth International Airport
(Energy Systems Laboratory, 2008-09)
Analysis of Emissions Calculators for a National Center of Excellence on Displaced Emissions Reductions (CEDER)
(2008-07-18)
In August 2004, the Environmental Protection Agency (EPA) issued guidance on quantifying the air emissions benefits from electric sector energy efficiency and renewable energy. Because there was no clear best strategy, ...
Detailed Analysis of Thermal Mass Effects in a Code-Traceable DOE-2 Simulation of the 2000 IECC for a Single-Family Residence in Texas: A Project for Texas' Senate Bill 5 Legislation for Reducing Pollution in Nonattainment and Affected Areas
(2008-07-18)
This study examines the thermal mass effects in a code-traceable DOE-2 simulation of the 2000 IECC (International Energy Conservation Code) for a single-family residence in Texas. This report is composed of two major ...
Test for Modeling Windows in DOE 2.1E for Comparing the Window Library with the Shading Coefficient Method for a Single-Family Residence in Texas
(2008-07-18)
This study examines the difference of the window simulation test between the Shading Coefficient (SC) and the Window Library (WL) Methods on DOE 2.1E of the 2000 IECC (International Energy Conservation Code) for single-family ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Commercial Office Buildings
(Energy Systems Laboratory, 2008-11)
This report presents detailed information about the recommendations for achieving 15% above-code energy performance for commercial office buildings complying with ASHRAE Standard 90.1-19991. To accomplish the 15% annual ...