Maintenance and Operations of Schools for Energy Efficiency
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
Maintenance and operations of schools with
energy efficiency as a priority can reduce annual
utility costs 3 to 30 percent. Most school
districts do not have an organized plan for
tracking energy usage or cost. Energy ...
Absorption Cooling Optimizes Thermal Design for Cogeneration
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
Contrary to popular concept, in most cases,
thermal energy is the real VALUE in cogeneration
and not the electricity. The proper consideration
of the thermal demands is equal to or more important than the electrical demands. ...
Prototype Passive Solar Buildings in Louisiana - A Hot-Humid Climate
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
This paper on prototype passive solar
buildings in Louisiana presents state of the art
passive solar design. According to U.S. Department
of Energy report, the annual energy consumption for
a single family detached dwelling ...
Operation Synopsis of Gas-Fired Double-Effect Absorption Chillers
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1986)
Absorption refrigeration systems are
one of the oldest systems available. The
fundamentals of absorption refrigeration
were formulated about 1777, and the first
successful absorption machine was developed
in 1850. The first ...
Design Considerations, Installation and Operation of the Two-Stage Parallel Flow Absorption Chiller
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
This presentation describes the actual design consideration and field operation experience of two-stage
parallel flow absorption chillers. The applications include new construction, rehabilitation of old HVAC
systems, ...
Application of an Energy Management System to a Distribution Center
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
Capital outlays for energy management must be economically attractive to warrant an expenditure. An energy management system has one of the most economic returns for an investment decision, if applied effectively. The ...
Ground-Coupled Heat Pump Applications and Case Studies
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1989)
The paper presents an overview of ground loops for
space-conditioning heat pumps, hot water, ice machines,
and water-cooled refrigeration in residential and commercial
applications. In Louisiana, a chain of hamburger ...
Optimal Control of Harvesting Ice Thermal Storage Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
Thermal storage is becoming a
standard consideration in HVAC and process
cooling systems. As the technology is
refined, more attention is being given to
minimize the energy consumption and power
demand requirements. This ...
Energy Management Retrofit for Arlington Independent School District
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1989)
Like many school districts in the southwest, the
Arlington Indement School District (AISD)
felt a need to upgrade their schools to maximize
their value for the gas and electricity being
used. They felt they needed to make ...
Small Sample Radon Testing of Homes in East Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
This paper covers the results of small sample radon testing of homes in East
Texas. The program was voluntary and participation was offered to a group