Terminal Box Airflow Reset: An Effective Operation and Control Strategy for Comfort Improvement and Energy Conservation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
A new terminal box operation and control
strategy, airflow reset, is developed to improve
building comfort and energy efficiency during
unoccupied and lightly occupied hours. The airflow
reset lowers the minimum airflow ...
Results of CC Follow-Up in the G. Rollie White Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
An investigation into the increase of energy
consumption of G. Rollie White Coliseum was part
of the persistence project[1], which investigates the
savings in energy consumption of ten buildings that
were commissioned by ...
Improving Boiler Efficiency Modeling Based On Ambient Air Temperature
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Optimum economic operation in a large
power plant can cut operating costs substantially.
Individual plant equipment should be operated
under conditions that are most favorable for
maximizing its efficiency. It is widely ...
Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Building energy consumption can be substantially
reduced after implementing what we call Extended
O&M Measures. The Extended O&M Measures are a
scientific refinement of traditional O&M measures.
Specifically, they ...
Thermal Characteristics and Systems of Residential Construction in College Station, Texas: 1981-1986
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1987)
This paper examines the energy efficiency
of residential construction in College
Station from 1981-1986. Housing sizes,
location, and construction activity by
various contractors are described using
data summarized from ...
Preliminary Measurements of the Energy Impact of Infiltration in a Test Cell
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
All existing computer models for calculating energy consumption of buildings assume that infiltration increases the heating and cooling load on a building by an amount equal to the mass flow rate of the infiltration times ...
A Methodology to Identify Monthly Energy Use Models from Utility Bill Data for Seasonally Scheduled Buildings: Application to K-12 Schools
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
The measured energy savings from retrofits
in buildings is often determined as the difference
between the energy consumption predicted by a
baseline model and the measured energy
consumption during the post retrofit ...
A Novel Procedure to Determine Optimal Air Static Pressure Set-points and Reset Schedules in VAV Air Handling Units
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
Air static pressure set-point or schedule for VAV
AHLJ systems is one of the most crucial
operational parameters for satisfy lug the building
load, maintaining the room comfort level and
saving energy costs. This paper ...
Impact of Nighttime Shut Down on the Prediction Accuracy of Monthly Regression Models for Energy Consumption in Commercial Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
Regression models of measured
energy use in buildings are widely used as
baseline models to determine retrofit savings
from measured energy consumption. It is less
expensive to determine savings from monthly
utility bills ...
The College Station Residential Energy Compliance Code
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
The City of College Station, Texas adopted a
new residential Energy Compliance Code in January,
1988. The code, which strengthens compliance
requirements in several areas, has received broadly
based support and acceptance ...