Search
Now showing items 11-20 of 24
The Value of the EWIT Computer Program in Identifying Economically Viable Retrofit Options for Existing Commercial Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
The Energy What If Tool (EWIT) program developed by the New Mexico firm of Area. Inc., offers architects
and environmental designers a new and viable means to model the energy performance of their building designs
while ...
A Gas-Fired Heat Pipe Zone Heater
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
A gas-fired vented zone heater has recently been developed by the Altar Corporation for Colorado State
University (CSU) under a Gas Research Institute (GRI) contract. The unit war developed for auxiliary heating
applications ...
A Research Into a New Method of Refrigeration Charging and the Effects of Improper Charging
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
The purpose of this report is to provide the results of research evaluating a new method of air conditioning
charging and the effects of improper charging. The method is the visual accumulator-charger device. The ...
Energy Management Experience in Public Schools
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
Public schools have a continuing dilemma of escalating energy costs, deferred maintenance, and enrollment shift. Schools have experienced difficulty in dealing with budgeting and subsequent control of maintenance
and ...
Electrical Demand Control
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
Almost every building owner or manager is interested in controlling electrical costs. Since the HVAC
system is a large user of electricity, this article will discuss what can be done in the HVAC system to
influence parts ...
A Study of the Electrical Energy Usage Patterns of a Texas Dairy
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
A one-year study was done on a modern dairy operation located in Hopkins County, Texas to determine the load
patterns and total energy use of the major electrical loads in the dairy. It was found that the vacuum pumps ...
Designing for Energy Conservation - The Cypress Fairbanks Medical Center Hospital
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 1984)
The concept of designing for energy conservation has long been a concern of Houston Lighting & Power (HL&P), culminating in the development of a local energy conservation design award competition in 1980. This competition ...
Utility Cost Analysis
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
One of the first steps in setting up an energy management program in a commercial building is determining
operating costs per energy consuming system through a utility cost analysis. This paper illustrates utility cost
analysis ...
Energy Study of City Hall Building: Port Arthur, Texas 1980-1981
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
As may be noted by the title, this is a detailed study of the energy consumption of this building. It
deals in the real world of actual energy utilization and it concludes with a "How To" approach to reduce and/or control ...
Design Considerations, Installation and Operation of the Two-Stage Parallel Flow Absorption Chiller
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1984)
This presentation describes the actual design consideration and field operation experience of two-stage
parallel flow absorption chillers. The applications include new construction, rehabilitation of old HVAC
systems, ...