Now showing items 350-369 of 660

    • Liu, C.; Bruner, H. L.; Deng, S.; Brundidge, T.; Turner, W. D.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      McKenzie Airport Terminal is located at Easterwood Airport, which is owned and operated by Texas A&M University. It was built in 1988. Most all HVAC equipment, which includes boiler, chiller, pumps, AHUs and exhaust fans, ...
    • Parsons, B. K.; Pesaran, A. A.; Bharathan, D.; Shelpuk, B. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      This paper examines the merits of coupling a desiccant dehumidification subsystem to a gas-engine- driven vapor compression air conditioner. A system is identified that uses a rotary, silica gel, parallel-plate dehumidifier. ...
    • Busch, J. F.; Warren, M. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      This paper describes an analysis of air conditioning performance under hot and humid tropical climate conditions appropriate to the Association of South East Asian Nations (ASEAN) countries. This region, with over 280 million ...
    • Andrews, J.; Lamontagne, J.; Piraino, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1989)
      This paper presents salient results of a utility-sponsored research project whose major objective was to identify all-electric technical means for energy-efficient independent control of sensible and latent cooling in ...
    • McClure, J. D.; Estes, J. M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      Investigations of indoor air qmlity or indoor environment problems were accomplished in seven different Texas schools. The schools were located in hot and humid climates. Comfort and mildew were the most frequent complaints. ...
    • Howel, E. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      Air Changes per Hour (ACH) are determined by construction and weather conditions. In this test, it was found that the ACH is equal to .59 plus .07 for every year of age the home has. The higher ACH values for age are due ...
    • McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used ...
    • Parker, D. S.; Sherwin, J. R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      A utility monitoring project has evaluated radiant barrier systems (RBS) as a new potential demand site management (DSM) program. The study examined how the retrofit of attic radiant barriers can be expected to alter utility ...
    • Katipamula, S.; Turner, W. D.; Murphy, W. E.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      An experimental study concerned with different modes of heal transfer in fibrous and cellulose insulating material is presented. A series of experiments were conducted using an attic simulator to determine the effects of ...
    • Vliet, G. C.; Askey, J. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      Similar sets of residences in Austin, Texas with electric water heaters and solar water heaters with electric back-up were monitored during 1982 to determine their instantaneous electric demands, the purpose being to ...
    • Poche', J. M.; Broussard, J. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      The Lafayette General Medical Center is a 332- bed, comprehensive regional medical facility. The Main Building was original a 7 story structure built in 1965. Prior to 1983, other than expansion work, there not been no ...
    • Kessling, W.; Holst, S.; Schuler, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      Thermal and visual comfort for the occupants of a room are not defined by air temperature only, but also radiation with its three components solar radiation, daylight and heat radiation has to be taken into account (among ...
    • Pate, M. E.; Todd, T. R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      This paper reports observations by the authors made in the course of performing field surveys and detailed analyses of approximately three hundred U. S. Navy buildings located in a humid climate. In the course of this ...
    • Kessling, W.; Peltzer, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      Solar air conditioning is an attractive technology to achieve comfortable room conditions, especially in hot and sunny climates. In particular air conditioning systems based on sorption technologies offer several advantages as ...
    • George, S. S.; Koved, M. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      This report documents a study that was conducted by XENERGY. Inc. for the CEC and a consortium of California utilities. The utilities primarily involved in the study were Pacific Gas and Electric Company (PG and E), ...
    • Roberts, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      The Institutional Conservation Program (ICP) provides matching grants to K-12 schools, colleges/universities, and hospitals for energy-related retrofit studies and the implementation of capital projects identified, analyzed, ...
    • O'Neal, D. L.; Bryant, J.; Carlson, K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      Experiences with instrumentation, installation and maintenance of building energy metering systems are presented. The building energy metering was installed in a variety of locations in programs handled by the Energy Systems ...
    • Jackson, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
    • Zhu, Y.; Batten, T.; Turner, W. D.; Claridge, D. E.; Giebler, T.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, B.; Hirchak, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The energy costs of heating, ventilating and air conditioning usually represents a large portion of the utility bills for a medical facility. One large, modem medical center located in the hot and humid region of southern ...
    • Heins, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007-12)