    • Katipamula, S.; Turner, W. D.; Murphy, W. E.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      An experimental study concerned with different modes of heal transfer in fibrous and cellulose insulating material is presented. A series of experiments were conducted using an attic simulator to determine the effects of ...
    • Vliet, G. C.; Askey, J. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      Similar sets of residences in Austin, Texas with electric water heaters and solar water heaters with electric back-up were monitored during 1982 to determine their instantaneous electric demands, the purpose being to ...
    • Poche', J. M.; Broussard, J. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      The Lafayette General Medical Center is a 332- bed, comprehensive regional medical facility. The Main Building was original a 7 story structure built in 1965. Prior to 1983, other than expansion work, there not been no ...
    • Kessling, W.; Holst, S.; Schuler, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      Thermal and visual comfort for the occupants of a room are not defined by air temperature only, but also radiation with its three components solar radiation, daylight and heat radiation has to be taken into account (among ...
    • Pate, M. E.; Todd, T. R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      This paper reports observations by the authors made in the course of performing field surveys and detailed analyses of approximately three hundred U. S. Navy buildings located in a humid climate. In the course of this ...
    • Kessling, W.; Peltzer, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      Solar air conditioning is an attractive technology to achieve comfortable room conditions, especially in hot and sunny climates. In particular air conditioning systems based on sorption technologies offer several advantages as ...
    • George, S. S.; Koved, M. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      This report documents a study that was conducted by XENERGY. Inc. for the CEC and a consortium of California utilities. The utilities primarily involved in the study were Pacific Gas and Electric Company (PG and E), ...
    • Roberts, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      The Institutional Conservation Program (ICP) provides matching grants to K-12 schools, colleges/universities, and hospitals for energy-related retrofit studies and the implementation of capital projects identified, analyzed, ...
    • O'Neal, D. L.; Bryant, J.; Carlson, K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      Experiences with instrumentation, installation and maintenance of building energy metering systems are presented. The building energy metering was installed in a variety of locations in programs handled by the Energy Systems ...
    • Jackson, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
    • Zhu, Y.; Batten, T.; Turner, W. D.; Claridge, D. E.; Giebler, T.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, B.; Hirchak, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The energy costs of heating, ventilating and air conditioning usually represents a large portion of the utility bills for a medical facility. One large, modem medical center located in the hot and humid region of southern ...
    • Heins, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007-12)
    • Karagiozis, A. N.; Desjarlais, A.; Salonvaara, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      In hot and humid climates the interior and exterior environmental loads that building envelopes must respond to are larger than many other climatic conditions. Moisture-originated failures in low-rise residential buildings ...
    • Meckler, G. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      Integrated ice thermal storage/sprinkler HVAC systems developed and applied by the author in several commercial applications shift a major portion of electric utility demand to cheaper off-peak hours, while also reducing ...
    • Shah, D. J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      During hot and humid periods, a comfortable indoor environment can be attained only by controlling both the dry-bulb temperature and the humidity in the space. Conventional thermostats control the ON/OFF status of a cooling ...
    • Phillips, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      Cogeneration is the production of electrical and thermal energy from a single fuel source. In comparison, electric power generation rejects the useful heat energy into lakes or other heat sinks. Electric generation alone ...
    • Mooney, B. L.; Porter, W. A. (Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
      Ventilated spaces in the built environment create unique and beneficial microclimates. While the current trends in building physics suggest sealing attics and crawlspaces, comprehensive research still supports the benefits ...
    • Haberl, J. S.; Culp, C.; Yazdani, B.; Fitzpatrick, T.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      Four areas in Texas have been designated by the U.S. Environmental Protection Agency (EPA) as non-attainment areas because ozone levels exceed the National Ambient Air Quality Standards (NAAQS) maximum allowable ...
    • Moyer, N. A.; Cummings, J. B.; Chasar, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      Increasing enrollment in grades K-12 coupled with the spiraling costs of construction has pushed school boards to develop more cost-effective classrooms, from the perspective of initial cost, longterm energy consumption, ...
    • Kennedy, S. R.; Quinn, C. B.; Henderson, J. E.; Vickery, R. G. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      Indoor air quality problems are diverse and often complex. Adverse indoor air quality problems can exist which create symptomatic conditions for building occupants. Often, the exact cause, or causes, of the substandard ...