    • Baltazar-Cervantes, J. C.; Haberl, J. S.; Culp, C.; Yazdani, B. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
      Power failures can occur for a variety of reasons. The consequences of such outages range from mere inconveniences to damaged equipment, ruined goods, lost revenue, and diminished safety. In all buildings lighting is among ...
    • Alghimlas, F.; Omar, E. A. (Texas A&M University (http://www.tamu.edu); Energy Systems Laboratory (http://esl.tamu.edu), 2004)
      Presently in Kuwait the code of practice for energy conservation in the air conditioned buildings implemented by the Ministry of Electricity and Water (MEW) which has been in effect since 1983 has no consideration taken ...
    • Liu, M.; Abbas, M.; Veteto, B.; Claridge, D. E.; Bruner, H. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      In the theory and modeling part, the principles of VAV box optimization are investigated. The simulations show that optimizing cold and hot deck reset schedules can significantly reduce the amount of energy consumption. During ...
    • Liu, M.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      Optimal hot and cold deck reset schedules can decrease simultaneous heating and cooling in VAV AHUs comparing with constant cold deck temperature operation. In this paper, optimization models are developed. The energy impacts ...
    • Liu, M.; Zhu, Y.; Claridge, D. E.; White, E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      Air static pressure must be maintained at a certain level leaving the air-handing unit (AHU) to force a suitable amount of air through the terminal boxes. However, an excessive static pressure level is often used due to ( ...
    • Guan, W.; Liu, M.; Wang, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      The impacts of the water loop management on the heating and cooling energy consumption are investigated by using model simulation. The simulation results show that the total thermal energy consumption can be increased by ...
    • Shaban, N.; Maheshwari, G. P.; Suri, R. K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Design conditions based on the meteorological data collected at two weather stations located less than 10 km away from each other within Kuwait City are presented for dry-bulb temperature (DBT) and web-bulb temperature ...
    • Weston, T. A.; Donihoo, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Air leakage in buildings located in hot and humid climates can result in excessive energy costs. Additionally, if uncontrolled moisture carried on air currents condenses within building components, it can potentially lead ...
    • Wei, G.; Claridge, D. E.; Sakuri, Y.; M. Liu (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      In a VAV (variable air volume) system, the set point of the static pressure (usually measured at 213 downstream of the main supply air duct) is maintained by modulating the fan speed or inlet guide vane position. The set ...
    • Munger, B.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      This paper describes an improved multipyranometer array (MPA) for the continuous remote measurement of direct and diffuse solar radiation. The MPA described in this paper is an improvement over previously published MPA ...
    • Thomas-Rees, S.; Barkaszi, S.; Chandra, S.; Chasar, D.; McIlvaine, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
    • Zhou, J.; Deng, S.; Turner, W. D.; Claridge, D. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      Optimum economic operation in a large power plant can cut operating costs substantially. Individual plant equipment should be operated under conditions that are most favorable for maximizing its efficiency. It is widely ...
    • Liu, C.; Bruner, H. L.; Deng, S.; Brundidge, T.; Turner, W. D.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
      McKenzie Airport Terminal is located at Easterwood Airport, which is owned and operated by Texas A&M University. It was built in 1988. Most all HVAC equipment, which includes boiler, chiller, pumps, AHUs and exhaust fans, ...
    • Parsons, B. K.; Pesaran, A. A.; Bharathan, D.; Shelpuk, B. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      This paper examines the merits of coupling a desiccant dehumidification subsystem to a gas-engine- driven vapor compression air conditioner. A system is identified that uses a rotary, silica gel, parallel-plate dehumidifier. ...
    • Busch, J. F.; Warren, M. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      This paper describes an analysis of air conditioning performance under hot and humid tropical climate conditions appropriate to the Association of South East Asian Nations (ASEAN) countries. This region, with over 280 million ...
    • Andrews, J.; Lamontagne, J.; Piraino, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1989)
      This paper presents salient results of a utility-sponsored research project whose major objective was to identify all-electric technical means for energy-efficient independent control of sensible and latent cooling in ...
    • McClure, J. D.; Estes, J. M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      Investigations of indoor air qmlity or indoor environment problems were accomplished in seven different Texas schools. The schools were located in hot and humid climates. Comfort and mildew were the most frequent complaints. ...
    • Howel, E. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      Air Changes per Hour (ACH) are determined by construction and weather conditions. In this test, it was found that the ACH is equal to .59 plus .07 for every year of age the home has. The higher ACH values for age are due ...
    • McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used ...
    • Parker, D. S.; Sherwin, J. R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)
      A utility monitoring project has evaluated radiant barrier systems (RBS) as a new potential demand site management (DSM) program. The study examined how the retrofit of attic radiant barriers can be expected to alter utility ...