Browsing ICEBO - International Conference for Enhanced Building Operations by Title
Now showing items 763-782 of 1002
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)Surveys conducted by the State of Florida Energy Offices Energy Conservation Assistance Program (ECAP) at the University of South Florida, over a 13 year period on a national basis, have, with repeatable results, shown ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)A method, based on simulation models, for active functional tests and optimization of coil energy recovery loop systems in Air Handling Units (AHUs) have been developed and a first version implemented in the program ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)European Parliament and the council announced on 16 December 2002, the Directive 2002/91/EC (Energy Performance Building Directive, EPBD). The European countries were asked to implement the EPBD within a time period of 3 ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)Interval data is the “new found” backbone of both supply-side and demand-side programs. The ability to acquire utility interval data has been available for years but mostly used by utility companies and large commercial customers ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)This paper reports the results of actual energy savings and the predicted energy savings of retrofitted one-story house located in Dhahran, Saudi Arabia. The process started with modeling the house prior to retrofitting ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)The main purpose of this research is to include uncertainty that lies in modeling process and that arises from input values when predicting system performance, and to incorporate uncertainty related to system controls in ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2013)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2013)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)For higher solar fraction and suitability for both heating and cooling, a solar heat pump system with seasonal storage was studied in this paper. The system scheme and control strategy of a solar heat pump system with ...
-
(Energy System Laboratory (http://esl.tamu.edu), 2008-10)In order to improve the energy performance of a district heating and cooling (DHC) plant, the expected performance of the plant is studied using simulations based on mathematical models. A complete heat source system model, ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)This paper simulated and analyzed the pressure differential of a laboratory animal room by CFD software. Under a certain wind speed, the windward side pressure distribution of laboratory animal room was studied, and the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2003)In 2001 the Texas Department of Criminal Justice Utilities and Energy Department (TDCJU& E) completed the installation of an extensive energy consumption metering system for their prison industries system. As the second ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)Due to sensor faults, it is a challenge to successfully detect and diagnose component faults in HVAC systems. The Principal Component Analysis (PCA) method has become a popular method to tackle this problem in recent years, ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)In northern China, there are a large number of space buildings divided in inner zone and exterior zone based on usage requirements. The exterior zone needs to be heated in winter and cooled in summer, while the inner zone ...
-
Procedure and Application for Determining the Cold Deck and Hot Deck Airflow in a Dual-Duct System (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)This paper introduces an innovative method to determine the cold and hot airflow through a dual-duct variable air volume (VAV) system. The actual building load can be identified based on the calculated airflow and temperature ...
-
(Texas A&M University (http://www.tamu.edu); Energy Systems Laboratory (http://esl.tamu.edu), 2007)Four areas in Texas, involving 16 counties, have been designated by the United States Environmental Protection Agency (EPA) as non-attainment areas because ozone levels exceed the National Ambient Air Quality Standard ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2013)Utility building developments in the near future face two mayor challenges. These challenges are closely related. The first one is the pressure to reduce the amount of energy needed to acclimatize the building and the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007)Our work deals with creating information assistance for commissioning (Cx) low-energy buildings throughout their life-cycle. We call this Embedded Commissioning in reference to the integration of persistent and reliable ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)In the next decade, digitalization of commissioning (Cx) is likely to be a key advance, in the field of AEC. This requires that as much of what we do manually, through word processing and spreadsheets can be done through ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2013)This paper addresses the issue of the misunderstandings surrounding the terms intelligent and smart when applied to modern buildings. The terms have increasingly been used interchangeably which has led to confusion for ...