Browsing ICEBO - International Conference for Enhanced Building Operations by Title
Now showing items 603-622 of 1002
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)Building Services Commissioning Association, BSCA, has been established in Japan as an NPO in order to propagate the building commissioning, especially HVAC commissioning, process among building and building services ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)Often in simplified energy analysis the use of bin weather data is employed for a more time efficient and better organized analysis than using the full 8760-hour annual weather data. It has been suggested that joint-frequency ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)This paper sets up a mathematical model of three-dimensional steady turbulence heat transfer in an air-conditioned room of multi-polluting heat sources. Numerical simulation helps identify key factors in displacement ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2001)An innovative AHU system is presented in this paper. The proposed AHU system is called a Laboratory Air Handling Unit (LAHU) system since it is most suitable for the buildings where one section (laboratory) has 100% exhaust ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)
-
LESSONS (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)
-
Lessons and Measures Learned from Continuous Commissioning(SM) of Central Chilled/Hot Water Systems (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2001)As it has been proved repeatedly that commissioning is very necessary for new construction and renovation/retrofit projects, we found continuous commissioningSM (CC) is an effective and efficient way to manage and optimize ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)In this paper, life cycle cost analysis (LCCA) of waste heat operated vapour absorption air conditioning system (VARS) incorporated in a building cogeneration system is presented and discussed. The life cycle cost analysis ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2014)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)A performance model has been programmed for solar thermal collector based on a linear, tracking parabolic trough reflector focused on a surface-treated metallic pipe receiver enclosed in an evacuated transparent tube: a ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Airflow dynamics significantly impact indoor thermal environment and human thermal comfort. Studies on the effects of airflow fluctuations on thermal comfort mainly focus on the effects of turbulence intensity and fluctuation ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2002)The Texas LoanSTAR program, which began in 1988, has produced over $110 million savings from energy conservation projects applied to state and local government buildings. One of the key features of LoanSTAR has been the ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2003)This paper addresses the effectiveness of using duct tape in sealing residential air distribution systems through two laboratory longevity tests. The first test involved the aging of common “core-to-collar joints” of ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)