Search
Now showing items 41-50 of 462
PL07 - Sand Management and Erosion Prediction in Subsea Multiphase Pumps
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, [2019])
Over the past ten years, subsea multiphase pumping has accomplished extraordinary technology breakthroughs. The drivers are the oil and gas companies requirements for deeper and more remote subsea production satellites ...
PL04 - Understanding the Effects of Selecting a Pump Performance Test Acceptance Grades
(Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, [2019])
There are good reasons for requiring the tightest test acceptance tolerances. That is why they are listed in industry accepted pump testing standards, ANSI/HI 14.6, ANSI/HI 11.6 and ISO 9906. There are also applications ...
CST17 - Case Study of Harsh Environment Impact on Gas Turbines Pre-Mature Failures in Malaysia Offshore Waters and Novel Approach in Resolving the Prolong Issues
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
A growing trend towards gas turbine applications in Harsh Environment which requires more challenging fuel and air qualities which has impacted the equipment reliability and long term durability. Major issues related with ...
CST09 - Analysis and countermeasure for Sulfide Stress Cracking of Centrifugal compressor
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
In case of copressors operated in evironment of wet hydrogen sulide, Sulfide Stress Craking could act critical mechanism of impeller failure. This case study deal with what make sulfide stress cracking and how to take a ...
CST10 - Resolution of High Vibration on Generator
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
The machine train consists of a HP/LP Steam turbine driving a Generator of 118 MW. The vibration was high on both the bearings of the Generator. The issue persisted for almost two years without the root cause being resolved. ...
CST01 - Hydrogen Recycle Gas Compressor Fouling Mitigation Using Higher Suction Temperature
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
During a normal run cycle the compressor performance started to decline (again) due to chloride contamination, a known issue. The usual approach was to shut the process unit down and turn the compressor off, then removing ...
PT01 - Monitoring Vibration and Other Critical Machine Conditions
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
Condition monitoring methods
Effectiveness of condition monitoring on rotating equipment
Value of, and ROI of, condition-based monitoring
Vertical pump monitoring
Below ground monitoring in vertical pumps
Vertical pump ...
P09 - Sealless Pumps
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
Types of sealless pumps and application limitations such as HP, pressure, temperature,
solids, etc.
Applications where sealless pumps have been successfully applied, and where they have
failed
Environmental performance in ...
PT01 - Considerations in Piping Plan 53B Applications
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
P05 - Centrifugal Pump Operation, Maintenance, and Reliability
(Turbomachinery LaboratoryTexas A&M Engineering Experiment Station, [2019])
Top Voted for Discussion in 2017: MI Inspections of pumps - (casing thickness) UT, on-line, shops; Methods for preventing reverse rotation, detecting reverse rotation; Hot alignment is there benefits, what temperature; ...