A Methodology For Calculating Integrated NOx Emissions Reductions from Energy Efficiency and Renewable Energy (EE/RE) Programs Across State Agencies in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2010)
This paper provides an update of the integrated NOx emissions reductions calculation procedures developed by the Energy Systems Laboratory (ESL) for the State of Texas. to satisfy the reporting requirements for Senate Bill ...
Water/Wastewater Engineering Report (Storm Sewer/Infiltration Sanitary Sewage Separation-M1 Model)
(2006-10-30)
In some cities, the municipal sewer system collects both storm water and sanitary sewage in the same pipes. During dry weather these sewers carry all the sanitary sewage to the wastewater treatment plant for treatment. ...
Development of a Residential Code-Compliant Calculator for the Texas Climate Vision Project
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007-12)
The United States Environmental Protection Agency (EPA) has designated four areas in Texas as having unacceptable ozone levels in excess of the National Ambient Air Quality Standard (NAAQS) limits, leading to a designation ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Volume III - Appendix, Annual Report to the Texas Commission on Environmental Quality, January 2006 - June 2007
(2009-02-20)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, ...
Baseline Report for the Fort Hood Army Base: September 2003 to October 2004
(2007-09-21)
This report presents electricity, natural gas and cooling baselines for the Thermal Plant, III Corp building,
Darnall Hospital, Main Substation, West Substation, and North Substation.
The baselines developed for this ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Vol. III - Technical Appendix
(2006-10-31)
The Energy Systems Laboratory, in fulfillment of its responsibilities under Texas Health and Safety Code
Ann. § 388.003 (e), Vernon Supp. 2002, submits its fourth annual report, Energy Efficiency/Renewable
Energy (EE/RE) ...
Development of a Web-Based, Emissions Reduction Calculator for Storm Water/Infiltration Sanitary Sewage Separation
(Energy Systems Laboratory (http://esl.tamu.edu), 2006)
This paper presents the procedures developed to
calculate the electricity savings and emissions
reductions from the infiltration of storm water into
sanitary sewage separation using a two-step
regression method: one ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Volume I - Summary Report, Annual Report to the Texas Commission on Environmental Quality, January 2006 - June 2007
(2008-01-23)
The Energy Systems Laboratory, at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. 2002, ...
Comparative Testing of the ESL's Code-Compliant Simulation Model and the FSEC's EnergyGauge Software
(2007-05)
This report presents a study of the comparison of the results of the ESL’s code-compliant
simulation model and the FSEC’s EnergyGauge (version 2.42).
Sensitivity analyses were performed by varying window-to-wall ratio ...