    The Measured Energy Impact of Infiltration Under Dynamic Conditions 

    Liu, M.; Claridge, D. E. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
    Energy consumption due to air infiltration is customarily assumed to equal the mass flow rate times the specific enthalpy difference between the inside and outside air. Anderlind showed theoretically that this represents ...
    Thumbnail

    Disaggregating Cooling Energy Use of Commercial Buildings Into Sensible and Latent Fractions From Whole-Building Monitored Data: Methodology and Advantages 

    Katipamula, S.; Reddy, T. A.; Claridge, D. E. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
    In hot and humid climates, where summers are both warm and humid, the latent cooling can be a significant portion of the total cooling load (as much as 40%). Typically the monitored data only includes whole-building heating ...
    Thumbnail

    Survey of Energy Use in Grocery Stores 

    Cox, R. L.; Haberl, J. S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
    This paper presents the results of an energy use survey assembled for 93 grocery stores in south Texas. All stores were of the same chain. Several conclusions were drawn. Total electricity consumption per square foot is ...
    Thumbnail

    Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System 

    Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
    The lecture hall of the Richardson Petroleum Building at Texas A&M University is a large lecture hall, with a total floor area of approximately 2500 ft^2. The lecture hall was served by a constant air volume (CAV) air ...
    Thumbnail

    Continuous Commissioning Results Verification and Follow-up For an Institutional Building: A Case Study 

    Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
    The Kleberg Building on the Texas A&M University campus is a teaching/research facility consisting of classrooms, offices and laboratories, with a total floor area of approximately 165,030 ft2. Continuous Commissioning ...
    Thumbnail

    The Cost-Effectiveness of Continuous Commissioning® Over the Past Ten Years 

    Bynum, J.; Claridge, D. E.; Turner, W. D.; Deng, S.; Wei, G. (Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
    Continuous Commissioning® data including savings, costs, and implemented measures from over 60 buildings and sites commissioned by staff from the Energy Systems Laboratory at Texas A&M University are presented. Measured ...
    Thumbnail

    Joint-Frequency Bins versus Conventional Bin Weather Data in Analysis of HVAC System Operation 

    Jones, A.; Baltazar, J. C.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)
    Often in simplified energy analysis the use of bin weather data is employed for a more time efficient and better organized analysis than using the full 8760-hour annual weather data. It has been suggested that joint-frequency ...
    Thumbnail

    Cooling-Only Prism Analysis of Eleven College Station Homes and Interpretation of Building Physical Parameters 

    Griffith, L.; Reddy, T. A.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
    A cooling-only PRISM analysis has been performed on eleven new residences in College Station using electricity billing data over an entire year. This study revealed that, provided one corrects for effects such as vacation ...
    Thumbnail

    Program Overview: The Texas LoanSTAR Program; 1989-August 1997 

    Turner, W. D.; Claridge, D. E.; O'Neal, D. L.; Haberl, J. S.; Heffington, W. M.; Harvey, T.; Sifuentes, T. (Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
    The Texas LoanSTAR mans to Save Taxes and Resources) program was conceived as a $98.6 million capital retrofit program for building energy efficiency. The funding source is petroleum violation escrow funds (PVE) from the ...
    Thumbnail

    Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation 

    Liu, M.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
    Optimal hot and cold deck reset schedules can decrease simultaneous heating and cooling in VAV AHUs comparing with constant cold deck temperature operation. In this paper, optimization models are developed. The energy impacts ...
    • 1
    • 2
    • 3
    • 4
    • . . .
    • 18

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of OAKTrustCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDepartmentTypeThis CommunityBy Issue DateAuthorsTitlesSubjectsDepartmentType

    My Account

    LoginRegister

    Discover

    Author
    Claridge, D. E. (178)
    Turner, W. D. (70)Haberl, J. S. (63)Liu, M. (35)Reddy, T. A. (28)Deng, S. (24)Zhu, Y. (19)Wei, G. (16)Katipamula, S. (13)Athar, A. (12)... View MoreSubjectLoanSTAR (27)energy efficiency (12)commissioning (9)energy conservation (8)control upgrades (7)EMCS (7)HVAC (7)ASHRAE (6)energy consumption (6)Monitoring and Analysis Program (6)... View MoreDate Issued2010 - 2013 (6)2000 - 2009 (81)1990 - 1999 (81)1987 - 1989 (10)TypeText (73)Presentation (16)Technical Report (11)Has File(s)Yes (178)
    Help and Documentation

    DSpace software copyright © 2002-2016  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    Atmire NV