Search
Now showing items 31-40 of 178
Restoration of Short Periods of Missing Energy Use and Weather Data Using Cubic Spline and Fourier Series Approaches: Qualitative Analysis
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The paper presents seventeen approaches that use
cubic splines and Fourier series for restoring short
term missing data in time series of building energy
use and weather data. The study is based on twenty
samples of hourly ...
Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at Texas A&M International University (TAMIU) Laredo, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
The physical plant director and staff at Texas A&M International University at Laredo do a very good job of maintaining TAMIU facilities. During our visit, however, we were able to identify several opportunities for improving ...
Engineering and Software Requirements of the Automated Building Commissioning Analysis Tool (ABCAT)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2005)
Engineering and Software requirements were measured using ABCAT
Potential Operation and Maintenance (O&M) Savings at the Dunbar Middle and Sims Elementary Schools
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential cost savings which may be
achieved by improving operational and maintenance (O&M) practices at Dunbar Middle
School and Sims Elementary School in the Fort Worth ...
Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Potential Operation and Maintenance (O&M) Savings at the State Capitol Complex
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential cost savings by improving
operations and maintenance (O&M) practices at eight buildings of the State Capitol
Complex, monitored by the LoanSTAR program. This ...
Guidelines for Measuring Air Infiltration Heat Exchange Effectiveness (IHEE), Submitted to the Texas Higher Education Coordination Board Energy Research Application Program Project #227
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report is presented to the Texas Higher Education Coordination Board as a
deliverable under the Energy Research and Applications Program Project #227, which
targeted reducing the design size of HVAC systems in houses ...
Potential Operation and Maintenance (O&M) Savings at Schools in the Ft. Worth Independent School District
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
As part of the Texas LoanSTAR program, 44 schools in the Fort Worth Independent
School District (FWISD) had lighting retrofits performed on there in late 1991. The
Energy Systems Laboratory of Texas A&M University is ...
LoanSTAR Monitoring and Analysis Program: Presentation Summary of the State Capitol Complex Building Operation and Maintenance Field Test
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
During the Fall of 1992 a comprehensive survey was conducted on
eight buildings at the State Capitol Complex to determine potential
operations and maintenance (O&M) savings opportunities. A verbal
report of the findings ...