    • Benz, R,; Staedter, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2008)
      Benz Air Engineering and the CompuNOx system focus on a controls approach to minimize emissions without exposing steam generation plants to an unbearable financial burden. With minimal system changes we use thorough system ...
    • Brown, T. S.; Michalek, R.; Reiter, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      Engelhard Corporation, established as an independent company on May 20, 1981, consists of the Engelhard Industries and the Minerals and Chemicals Divisions of the former Engelhard Minerals and Chemicals Corporation. Engelhard ...
    • Parris, Mark; Cameron, Dan (Texas A&M University. Turbomachinery Laboratories, 1999)
      At most industrial facilities, the engineering, maintenance, and operation groups are under great pressure to increase reliability and also reduce costs. This paper discusses the role of operators in achieving low cost ...
    • Evers, Gerald Wayne; Smith, Gerald R. (Texas A & M University. Libraries, 2002)
    • Greenwood, Stuart A. (Texas A&M University. Turbomachinery Laboratories, 2000)
      The need to control exhaust emissions from stationary power sources is dictated by environmental regulations that limit the amount of smoke (particulates), sulfur dioxide, carbon monoxide, hydrocarbons, and oxides of ...
    • Polley, G. T. (Energy Systems Laboratory (http://esl.tamu.edu), 2002-04)
      In this paper we look at various options available for the reduction of energy consumption in distillation systems. For binary systems, we look at how heat pumps can be used. With multi-component systems, process integration ...
    • Schrag, T.; Waldhoff, C.; Radler, J.; Lenzen, B. (Energy Systems Laboratory (http://esl.tamu.edu), 2008-10)
      The new government building with ca. 14.000 m2 gross floor area in Innsbruck/Tirol was designed as a low energy office building. As little technical installations as possible and as much room comfort as achievable: These ...
    • Weaver, Firm L. (Texas A&M University. Turbomachinery Laboratories, 1983)
      Bucket failures have been known to occur on the later stages of industrial type steam turbines after prolonged operational life of as much as five or six years. All of these failures are characteristically fatigue in nature. ...
    • Kocur, John A.; Hayles, George C. (Texas A&M University. Turbomachinery Laboratories, 2004)
      A catalytic gas process compressor experienced low frequency vibrations in excess of trip levels following installation of a honeycomb balance piston. After 12 years of operation, low seal oil differential forced an unplanned ...
    • Von Nimitz, Walter W. (Texas A&M University. Gas Turbine Laboratories, 1975)
      Low frequency vibrations at centrifugal compressor and pump installations are usually discarded as unlikely. However, severe acoustically excited vibrations at frequencies as low as 5 or 10 Hz have been observed at a number ...
    • Shyr, S. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
      An innovative energy conservation project involving one of the largest known plate heat exchangers in Canada saves energy for Polysar Limited. This unique retrofit project has not only increased the recovery of low grade ...
    • Alcocer, J. L. B.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
      This paper discusses an effort to develop low impact, affordable, low income houses for Mexico. Low impact houses are defined as houses with energy and water needs that are substantially reduced below levels corresponding ...
    • McDonald, G. V.; Pemberton, H. B.; Roberson, W. E. (Texas A & M University. Libraries, 1992)
    • O'Brien, W. J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      With today's high fuel prices, energy conservation projects to utilize low level waste heat have become more attractive. Exxon Chemical Company Central Engineering has been developing guidelines and assessing the potential ...
    • Gilbert, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1980)
      The intent of this paper is to examine the methods and economics of recovering low level heat through heat pumps and vapor recompression. Actual commercially available equipment is considered to determine the near-term and ...
    • Shaw, Patrick; Prichard, Kent (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2015)
      Problem: Ethane pumps with process lubricated; ‘liquid (wet)’ 2CW-CS, plan 11, 76, seals suffered a high frequency of seal failures from initial commissioning in November 2009 •2 fractionator units each with 2 ethane ...
    • Villarino, Mario A. (2009-05-04)
      Using low-stress methods of handling dairy cattle is efficient in terms of time and labor. This publication explains how cattle's natural instincts affect their responses, and ways handlers can use that knowledge to make ...
    • Villarino, Mario A. (2009-05-04)
      Using low-stress methods of handling dairy cattle is efficient in terms of time and labor. This publication explains how cattle's natural instincts affect their responses, and ways handlers can use that knowledge to make ...
    • Ash, A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      This paper discusses the performance of an off peak ice storage air conditioning system installed on an office warehouse building in Dallas, Texas. The system also incorporates a low temperature (45 degree) air distribution ...
    • Shook, J. R.; Luttenberger, D. B. (Energy Systems Laboratory (http://esl.tamu.edu), 1986-06)
      Low temperature corrosion proof heat exchangers designed to reduce boiler flue gas temperatures to 150°F or lower are now being commercially operated on gas, oil and coal fired boilers. These heat exchangers, when ...