Show simple item record

dc.contributor.otherAir Liquide A&D
dc.contributor.otherAir Products
dc.contributor.otherAir Liquide Large Industry U.S.
dc.creatorThomas, J. Kelly
dc.creatorGeng, Jihui
dc.creatorRodriguez
dc.creatorJallais, Simon
dc.creatorVyazmina, Elena
dc.creatorMiller, Derek
dc.creatorLindberg, Bill
dc.creatorPawulski, Richard
dc.date.accessioned2021-06-11T18:56:00Z
dc.date.available2021-06-11T18:56:00Z
dc.date.issued2018
dc.identifier.urihttps://hdl.handle.net/1969.1/193495
dc.descriptionPresentationen
dc.description.abstractThe ignition of a hydrogen-air mixture that has engulfed a typical set of ambient vaporizers (i.e., an array of finned tubes) may result in a deflagration-to-detonation transition (DDT). Simplified curve-based vapor cloud explosion (VCE) blast load prediction methods, such as the Baker- Strehlow-Tang (BST) method, would predict a DDT given that typical ambient vaporizers would be rated as medium or high congestion and hydrogen is a high reactivity fuel (i.e., high laminar burning velocity). Computational fluid dynamic (CFD) analysis of a single vaporizer of typical construction was carried out using the FLACS code to evaluate the potential for a DDT with a vaporizer engulfed by a hydrogen-air mixture at the worst-case concentration. This analysis showed that while significant flame acceleration occurs within the vaporizer, as expected, a DDT is not predicted. However, the analysis did indicate that a DDT may occur for two or more closely spaced vaporizers. This is relevant since multiple vaporizers are frequently present at industrial installations and are typically placed closely together to limit the required area. Spacing adjacent vaporizers further apart could preclude a DDT. However, specification of the spacing to preclude a DDT would require refined CFD analysis and/or testing, neither of which has been performed at this time. This paper also discusses the application of simplified VCE blast load methods to ambient vaporizers engulfed in a flammable hydrogen-air cloud in order to illustrate the impact of a DDT.en
dc.format.extent16 pagesen
dc.languageeng
dc.publisherMary Kay O'Connor Process Safety Center
dc.relation.ispartofMary K O'Connor Process Safety Symposium. Proceedings 2018.en
dc.rightsIN COPYRIGHT - EDUCATIONAL USE PERMITTEDen
dc.rights.urihttp://rightsstatements.org/vocab/InC-EDU/1.0/
dc.subjectHydrogran DDTen
dc.titlePotential for Hydrogen DDT with Ambient Vaporizersen
dc.type.genrePapersen
dc.format.digitalOriginborn digitalen
dc.publisher.digitalTexas &M University. Libraries


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record