Cool Storage Applications in the Texas LoanSTAR Program: Overview and Preliminary Results
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Cool Storage Systems (CSS) are becoming a popular demand side management tool for utilities because that helps them avoid costly plant expansions and reduces summer-time peak electricity demand. This paper presents an ...
Thermal Energy Measurement with Tangential Paddlewheel Flow Meters: Summary of Experimental Results and in-situ Diagnostics
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
Recently third-party financing has become a popular mechanism for funding energy conservation retrofits in commercial/institutional buildings. Although many successful projects have been heralded by the press quite a few ...
Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects: Preliminary Engineering Survey, USDOE Forrestal and Germantown Facility, Summary Report, USDOE Office of Conservation and Energy
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
The purpose of this preliminary engineering survey of the USDOE Forrestal and Germantown
facilities is to determine whether existing EMCSs can be used for monitoring energy retrofits, and in
the case where this is not ...
The USDOE Forrestal Lighting Retrofit: Analysis of Electricity and Thermal Savings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1995)
This report provides an overview of the lighting retrofit and the resultant electricity and thermal savings. It presents results from the whole-building monitoring effort that show that the measured gross electricity savings ...
Use of Energy Management and Control Systems for Performance Monitoring of Retrofit Projects: Final Summary Report for USDOE Office of Conservation and Energy, Final Revision, March 1993
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Traditionally, Energy Management and Control Systems (EMCSs) have been used to control
HVAC, lighting, fire and security systems in buildings. Few EMCSs are used for long term
trending and analysis of energy use (i.e., ...
Internet Data logging and Display
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
The current energy savings technology relies on conventional data logging systems, in which two major barriers exist. Formost is the fact that retrieving the energy data is not convenient, and the cost of the data logging ...
Automated Data Quality Analysis Research and Development
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
The Automated Data Quality process development is an effort to automate the analysis and
monitoring of the Energy Systems Lab's (ESL) polling and energy data process. Polling status
refers to basic telecommunication line ...
Access and Display of LoanSTAR Data via the Internet
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)
The Energy and Environmental Data System (EEDS) is a web application that facilitates web-based viewing of the Energy Systems Lab's extensive building energy databases. EEDS is the initial framework for a growing set of ...
Program Overview: The Texas LoanSTAR Program; 1989-October 1999, A 10-Year Experience
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
The Texas LoanSTAR (Loans to Save Taxes and Resources) program was conceived as a $98.6 million capital retrofit program for building energy efficiency. The funding source is petroleum violation escrow funds (PVE) from the ...
Potential Energy Savings from Optimized Schedule and Economizer Cycles in the Moody Library at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study which was initiated in order to estimate the potential energy savings due to optimizing the HVAC operation schedule and using economizer cycles in the Moody Library Building ...