Using Simulation Models for District Chilled Water Distribution Systems Design
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
The capital investment for the distribution system is often the most expensive portion of a district heating
and cooling system, which usually constitutes 50 to 70% of the total cost. Because of high initial cost, it is
very ...
Correcting Thermal Distribution Problems for a Large University Campus
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Texas A&M University main campus in
College Station consists of 114 buildings served by
two central plants. The two main campus loops are
more than 50 years old with a total piping length for
each loop in excess of 13 ...
Maximizing Commercial Hydraulic Software Simulation in Thermal Distribution System Continuous Commissioning
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Shut Down Schedule Optimization with Outdoor Humidity Level
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The supply air temperature set point for a singleduct
constant air volume air handling unit (AHU)
system is often reset based on either return air
temperature or outside air temperature in order to
reduce simultaneous ...
Continuous Commissioning® of the Matheson Courthouse in Salt Lake City, Utah
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2003)
The Utah Energy Office, located in the Department
of Natural Resources (DNR), Utah Department of
Facilities Construction and Management (DFCM),
and engineers from the Energy Systems Laboratory at
Texas A&M University teamed ...
LoanSTAR After 11 Years: A Report on the Successes and Lessons Learned from the LoanSTAR Program
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The Texas LoanSTAR program, which began in
1988, has produced over $110 million savings from
energy conservation projects applied to state and
local government buildings. One of the key features
of LoanSTAR has been the ...
Rehabilitation of Secondary Heating and Cooling Systems - Case Study
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Continuous Commissioning (CCSM) was performed
on the Texas A&M Large Animal Hospital in
October 1996 and as a result, significant savings were
achieved. Subsequently, the building chilled water
and hot water energy consumption ...
Continuous Commissioning of a Central Chilled Water & Hot Water System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
A central chilled water / hot water system
provides cooling / heating energy from central utility
plants to multiple customers (buildings) through
campus distribution loops. To effectively transport
the chilled water and ...
Development of a Procedure for the Predictive Control Strategy of a Chilled Water Storage System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Thermal energy storage systems store the
thermal energy produced by the chiller plant in
periods of off-peak electrical demand or when
cheaper electricity is available. The stored thermal
energy is then withdrawn from the ...