Reducing Pump Power Consumption by 40% (1000 KW) Through Improved Pump Management in a Central Plant
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
Chilled water system data collection and field
measurements performed at the Central Utility Plant
of Texas A&M University revealed that 30 - 50 % of
the primary pump head is consumed by manual and
automatic valves being ...
Simulation and Optimization on Power Plant Operation Using Sega's EOP Program
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The operation of a cogeneration power plant is
complicated. The Energy Optimization Program
(EOP, software made by SEGA, Inc.) was designed
to simulate and optimize the operation of TAMU
power plant. All major plant ...
Commissioning of A Large Office Building in Texas - A Case Study
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
This case study involves commissioning of a
large office building in the hot and humid climate of
south Texas. The commissioning involved the
installation of a VFD (Variable Frequency Drive) on
a chilled water pump, improved ...
LoanSTAR Monitoring and Analysis Program: Presentation Summary of the State Capitol Complex Building Operation and Maintenance Field Test
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
During the Fall of 1992 a comprehensive survey was conducted on
eight buildings at the State Capitol Complex to determine potential
operations and maintenance (O&M) savings opportunities. A verbal
report of the findings ...
Continuous Commissioning(SM) of a Thermal Storage System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2001)
Chilled water thermal storage systems can
reduce the electrical demand charge during the onpeak
months. However, operational problems such as
the inability to fully charge the system or premature
discharge of the stored ...
A Novel Procedure to Determine Optimal Air Static Pressure Set-points and Reset Schedules in VAV Air Handling Units
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
Air static pressure set-point or schedule for VAV
AHLJ systems is one of the most crucial
operational parameters for satisfy lug the building
load, maintaining the room comfort level and
saving energy costs. This paper ...
Integrated Commissioning for a Large Medical Facility
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The energy costs of heating, ventilating and
air conditioning usually represents a large
portion of the utility bills for a medical facility.
One large, modem medical center located in the
hot and humid region of southern ...
Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
The supply air temperature set point for a singleduct
constant air volume air handling unit (AHU)
system is often reset based on either return air
temperature or outside air temperature in order to
reduce simultaneous ...
Continuous Commissioning of a Central Chilled Water & Hot Water System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
A central chilled water / hot water system
provides cooling / heating energy from central utility
plants to multiple customers (buildings) through
campus distribution loops. To effectively transport
the chilled water and ...
Development of a Procedure for the Predictive Control Strategy of a Chilled Water Storage System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Thermal energy storage systems store the
thermal energy produced by the chiller plant in
periods of off-peak electrical demand or when
cheaper electricity is available. The stored thermal
energy is then withdrawn from the ...