(Energy Systems Laboratory (http://esl.tamu.edu), 1994-04)The emphasis on reduction of NOx as a precursor to street level ozone has increased the need for technologies capable of reducing NOx (>95%) to very low levels in major metropolitan areas from a wide variety of sources. ...
-
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-04)Localized NOx reduction during Ozone Alerts is a problem of increasing importance to process industries in and around heavily industrialized areas. New regulations by local and federal agencies are being developed, and ...
-
(Energy Systems Laboratory, 2008-09)
-
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-10)ESL used the Texas Commission on Environmental Quality’s (TCEQ) Guide for Incorporating Energy Efficiency/Renewable Energy (EE/RE) Projects into the SIP for local entities dated February 6, 2004 to survey potential projects ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2004)Four areas in Texas have been designated by the United States Environmental Protection Agency (EPA) as non-attainment areas because ozone levels exceed the National Ambient Air Quality Standard (NAAQS) maximum allowable limits. ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007)Benz Air Engineering and the CompuNOx system focus on a controls approach to minimize emissions without exposing steam generation plants to an unbearable financial burden. With minimal system changes we use thorough system ...
-
(2006-10-27)The Energy Systems Laboratory (ESL) at the Texas Engineering Experiment Station, Texas A&M University System was contracted to fulfill a Continuous Commissioning® (CC®)project on the Rent-a-Car facility (RAC) of the ...
-
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1990-06)Every electric utility forecaster predicts a tremendous increase in the amount of Non-Utility Generation (NUG) and Independent Power Production (IPP) activity. We will not bore the reader with yet another series of tables ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Cold air distribution systems may reduce the operating energy consumption of air-conditioned air supply system and improve the outside air volume percentages and indoor air quality. However, indoor temperature patterns and ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)In view of the influence of humidity of room air on room heat load, indoor environment and building energy consumption in underground intermittent air-conditioning systems, numerical simulation was used to dynamically ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)As new equipment, the channel wheel fresh air ventilator has become increasingly popular in recent years. However, when such equipment is operated under low ambient temperature in the freezing area in winter, the formation ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Air source heat pump water heaters (ASHPWH) are becoming increasingly popular for saving energy, protecting the environment and security purposes. The water temperature distribution in the tank is an important parameter ...
-
(1994-12)Non-linear finite element models were developed to simulate transient heat and mass transfer in the soil surrounding the ground heat exchangers of ground-coupled heat pumps (GCHPs) operating in the cooling mode. Parametric ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Energy-efficient and cost-effective space conditioning in offices and other commercial buildings usually use the underfloor space for the supply air static-pressure plenum. The airflow in a plenum of the underfloor air ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Displacement ventilation (DV) is a promising ventilation concept due to its high ventilation efficiency. In this paper, the application of the CFD method, the velocity and temperature fields of three-dimensional displacement ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)In this study, the rectangular phase change storage tank (PCST) linked to a solar-aided ground source heat pump (SAGSHP) system is investigated experimentally and theoretically. The container of the phase change material ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)Since athletes' records can vary greatly depending on air velocities in sports halls, airflow patterns have played a very important role in HVAC design in gymnasiums. HVAC designers and researchers have paid more and more ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)In the present paper, a kind of enclosed phase change material (PCM) used in solar and low-temperature hot water radiant floor heating is investigated. On the basis of obtaining the best performance of PCM properties, a ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)The unglazed transpired solar air collector is now a well-recognized solar air heater for heating outside air directly. In this article, researchers introduced numerical simulation tools into the solar air collector research ...
-
(Energy Systems Laboratory, 2011)