Now showing items 3949-3968 of 4879

    • Grosskopf, K. R.; Cutlip, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
    • Staff, Energy Systems Laboratory (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1993)
    • Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)
      This document contains a sample M&V plan that has been prepared in accordance with the Texas Guidelines for Measurement and Verification for Energy Performance Contracts. This sample M&V plan was extracted from the March ...
    • Hernandez, J. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2013)
    • Pollock, C. B. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1981)
      Energy management in modern refineries is becoming more difficult as the real cost of in-house and purchased fuel escalates and the quality of feed stocks decreases. Furnace tube maintenance has been made more complex by ...
    • Al-Dossary, F. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)
      Saudi Aramco Gas Operations (GO) created energy efficiency strategies for its 5-year business plan (2011-2015), supported by a unique energy efficiency program, to reduce GO energy intensity by 26% by 2015. The program ...
    • Ratkowski, D. P. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2007)
      Empirical analysis of stack gas heating value allowed the Afton Chemical Corporation Sauget Plant to reduce natural gas flow to its process flares by about 50% while maintaining the EPA-required minimum heating value of ...
    • Monroe, R. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1981)
      There are several ways to save energy in wet cooling towers and air cooled heat exchangers using axial fans. This paper will discuss ways to improve fan system efficiency in wet and dry towers both during the design phase ...
    • Chung, C. W. (Energy System Laboratory (http://esl.tamu.edu), 1985-05)
      Two level demand makes it possible to use two systems for refrigeration and save energy and money. An example of this type of refrigeration, consisting of an ammonia absorption refrigeration (AAR) unit and a mechanical ...
    • Puskar, J. R. (Energy Systems Laboratory (http://esl.tamu.edu), 1998-04)
      This paper speaks to a common problem in a lot of industrial and institutional boilerhouses. Most boilerhouses do an excellent job at collecting information. Circular chart recorders churn out pressures, temperatures, and ...
    • Zimmermann, F. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2008)
    • John, T. P. (Energy Systems Laboratory (http://esl.tamu.edu), 1998-04)
      Texas Petrochemicals operates a butane dehydrogenation unit producing MTBE for reformulated gasoline that was originally constructed when energy was cheap and prior to environmental regulation. The process exhausts 900,000 ...
    • McReynolds, C. J. (Energy Systems Laboratory (http://esl.tamu.edu), 1986-06)
      Today's emphasis is on saving dollars -- not just Btu's. Ford spent $900 million on energy in 150 plants worldwide last year. In 1972, Ford's energy bill was $238 million. Last year's bill would have been 35% higher ...
    • Trojanowski, D.; Parfomak, P. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1993-03)
      Compressed air systems are among the most common and least efficient electrical end uses in industrial plants. Over 50% of plants use compressed air systems. According to various estimates, between 20% and 35% of the energy ...
    • Wilson, T.; Bell, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
      In September 2008, PCS UtiliData commissioned an Industrial Voltage Optimization system at the Plum Creek Timber Medium Density Fiberboard facility in Columbia Falls, Montana. The system was based upon the AdaptiVolt(TM) ...
    • Francis, G. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1982)
      It is a particular pleasure for me to be here with you today to take part in the Texas Industrial Commission's 1982 Industrial Energy Conference. 'Energy', being an essential, if not the most essential part of the economic ...
    • Tomlin, W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1980)
      It is a particular pleasure for me to be here with you today to take part in the Texas Industrial Commission's Second Annual Industrial Energy Conference. "Energy" being an essential, if not the most essential part of the ...
    • Woodruff, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)
    • Woodruff, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2010)