Search
Now showing items 21-30 of 46
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Preliminary Report: Integrated NOx Emissions Savings from EE/RE Programs Statewide
(2008-08-29)
The Energy Systems Laboratory (ESL), at the Texas Engineering Experiment Station of the Texas A&M University System, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. 388.003 (e), Vernon Supp. ...
Energy Efficiency / Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Vol. III – AppendixAnnual Report to the Texas Commission on Environmental Quality, Sept. 2003 to Aug. 2004
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2004)
The Energy Systems Laboratory, in fulfillment of its responsibilities under Texas Health and Safety Code Ann. § 388.003 (e), Vernon Supp. 2002, submits its third annual report, Energy Efficiency/Renewable Energy (EE/RE) ...
Texas’ Senate Bill 5 Legislation for Reducing Pollution in Non-Attainment and Affected Areas: Annual Report to the Texas Natural Resource Conservation Commission
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
This is the first annual report by the Energy Systems Laboratory, which covers the Laboratory's efforts to support Senate Bill 5. In this report the accomplishments and progress to date are presented, along with recommendations, ...
Texas’ Senate Bill 5 Legislation for Reducing Pollution in Non-Attainment and Affected Areas: Report for the TERP Advisory Board Meeting
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)
This report outlines the Energy Systems Laboratory's responsibilities in Senate Bill 5, accomplishments to date, recommendations to the TERP Advisory Group, and problems encountered to date and what is needed to fulfill ...
Recommendations for 15% Above-Code Energy Efficiency Measures for Residential Buildings
(Energy Systems Laboratory, 2008-11)
This report presents detailed information about the recommendations for achieving 15% above-code energy performance for single-family residences. The analysis was performed using a simulation model of an International ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP), Volume II – Technical Report, Annual Report to the Texas Commission on Environmental Quality September 2002 – August 2003
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)
The Energy Systems Laboratory (Laboratory) is pleased to provide our second annual report, Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan to the Texas Council on Environmental Quality (TCEQ) ...
15% Above-Code Energy Efficiency Measures for Commercial Buildings in Texas
(Energy Systems Laboratory, 2007-08)
In the pages that follow, 15% above-code measures for new commercial buildings are presented
for the 41 non-attainment and affected counties in Texas, separated by climate area. Each page
contains a description of the ...
NOx, SOx and CO2 Emissions Reduction from Continuous Commissioning® (CC®) Measures at the Rent-A-Car Facility in the Dallas-Fort Worth International Airport
(2006-10-27)
The Energy Systems Laboratory (ESL) at the Texas Engineering Experiment Station, Texas A&M University System was contracted to fulfill a Continuous Commissioning® (CC®)project on the Rent-a-Car facility (RAC) of the ...
A Methodology for Calculating Emissions Reductions from Renewable Energy Programs and Its Application to the Wind Farms in the Texas ERCOT Region
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007-12)
Recently Texas Legislature required adding 5,880 MW of generating capacity from renewable energy technologies by 2015, and 500 MW from non-wind renewables. This legislation also required the Public Utility Commission (PUC) ...
Impact of the Implementation of the 2000/2001 IECC on Residential Energy Use in Texas: Preliminary Verification of Residential Energy Savings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Power failures can occur for a variety of reasons.
The consequences of such outages range from mere
inconveniences to damaged equipment, ruined goods,
lost revenue, and diminished safety.
In all buildings lighting is among ...