The Temperature and Relative Humidity Control in Cushing Library
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Cushing Library located on TAMU campus is a
special building, which needs precise temperature
and relative humidity control, because it stores a
number of rare collections and memorial books.
There are five air-handling ...
Analysis of Texas LoanSTAR Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
The analysis effort during the first year of the Texas LoanSTAR
Monitoring and Analysis Program has emphasized selection and
development of baseline analysis techniques to cover the range
of buildings expected in the ...
Experiences on the Implementation of the 'Energy Balance' Methodology as a Data Quality Control Tool: Application to the Building Energy Consumption of a Large University Campus
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
As the energy costs have been increasing the more energy efficient measures have been promoted in the buildings sector, the reliability of energy consumption data has been attracting significant attention. For example, the ...
Considerations for Energy Efficient Showers in Hot-Humid Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1989)
Measurements have been conducted on
four low-flow showerheads currently
recommended by utilities. These
measurements were made to determine
expected cost savings in two prison
installations, based on water
savings, sewer ...
Energy Efficiency Design Evaluation for the Texas Department of Corrections
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
A rapid, but comprehensive review of the
electrical, mechanical and thermal systems in the
maximum security prisons to be built in Amarillo and
Gatesville, TX recommended 10 measures for each
prison which offered annual ...
Continuous Commissioning® of an Office/Laboratory Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2005)
Procedures for Filling Short Gaps in Energy Use and Weather Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
Filling short gaps (a few hours) in hourly
energy use and weather data can be useful for (i)
retrofit savings analysis and calculation, and for (ii)
diagnostic purposes. The paper evaluates four
methods for rehabilitating ...
Improved Analysis Methods for Retrofit Savings and Energy Accounting (ERAP #227)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1990)
This report summarizes progress through November, 1990 for ERAP project No. 227, "Improved Analysis Methods for Retrofit Savings and Energy Accounting." The major objectives of this project are to: (1) determine the energy ...
The Brazos Valley Energy Conservation Coalition, Part of the Rebuild America Program in Texas: Program Update
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
The Rebuild America program is network of
community-based partnerships that rebuilds
communities by promoting the efficient use of
energy. Rebuild America is coordinated at the
national level by sponsorship through the ...
Improved Air Volume Control Logic for VAV Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2000)
In a VAV (variable air volume) system, the set
point of the static pressure (usually measured at 213
downstream of the main supply air duct) is
maintained by modulating the fan speed or inlet
guide vane position. The set ...