Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
Since 2004, the County of Los Angeles have retrocommissioned over 4 million square feet and additional RCx work is underway. The scope of the HVAC retrocommissioning (RCs) involved systematic investigation of mechanical, ...
Achieving High Chilled Water Delta T Without Blending Station
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
Typically a blending station is designed to ensure that its user is able to avoid low chilled water return temperature in the district cooling system. When the chilled water return temperature drops to a low limit, building ...
Economizer Control Using Mixed Air Enthalpy
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
Enthalpy economizer can theoretically save more energy than temperature based economizer. However, the requirement of outdoor air humidity measurement in the traditional enthalpy economizer control made it impossible. A ...
Statewide Air Emissions Calculations from Wind and Other Renewables, Summary Report
(2007-10-30)
The 79th Legislature, through Senate Bill 20, House Bill 2481 and House Bill 2129, amended Senate Bill 5
to enhance its effectiveness by adding 5,880 MW of generating capacity from renewable energy
technologies by 2015, ...
Experiences on the Implementation of the 'Energy Balance' Methodology as a Data Quality Control Tool: Application to the Building Energy Consumption of a Large University Campus
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2007)
As the energy costs have been increasing the more energy efficient measures have been promoted in the buildings sector, the reliability of energy consumption data has been attracting significant attention. For example, the ...
Building HVAC Control System Interaction Issues: Two Case Studies
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007)
Direct Digital Control (DDC) allows HVAC equipment to be controlled at an upper level (supervisory control) through commands from a central system, or at a lower-level (local-loop control) by local controllers. The various ...
Continuous Commissioning of Commercial Kitchen and Dining Facilities - Case Study
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007)
Commercial kitchens usually require a large amount of ventilation air and high ventilation rates. Today's typical kitchens and dining facilities are often equipped with Make-up Air Fans (MAF) or dedicated Make-up Air Units ...
Recommendations for 15% Above-Code Energy-Efficiency Measures for Commercial Office Buildings
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007-12)
This paper presents an overview of the recommendations for achieving 15% above code energy performance for commercial office buildings complying with ASHRAE Standard 90.1-1999. To accomplish the 15% annual energy consumption ...
Application of Various HVAC Simulation Programs and Visual Tools to Commissioning
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 2007)
Various existing HVAC system simulation programs and visualization tools are considered to be potentially powerful tools for commissioning. Although not originally developed as commissioning tools, these programs facilitate ...
Energy Efficiency/Renewable Energy Impact in the Texas Emissions Reduction Plan (TERP)
(Energy Systems Laboratory, Texas A&M University System, 2007-07)
This report is a summary of the renewable energy projects installed throughout Texas
after the year 2000. The collection of these projects was done in response to the Energy
System Laboratory’s requirement to fulfill its ...