Search
Now showing items 11-20 of 108
Potential Operation and Maintenance (O&M) Savings in the Basic Science Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential energy savings due to optimizing the Heating, Ventilation and Air Conditioning (HVAC) operation schedule in the Basic Science Building at University of Texas ...
Summary of UTMB O&M Project: Energy Conservation Potential in Five Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report is a summary of five reports (references 1 to 5) which provided detailed
descriptions of an O&M investigation of the following five buildings on the UTMB
campus: 1) John Sealy North Building(JSN); 2) Clinical ...
Using Fourier Series to Model Hourly Energy Use in Commercial Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
Fourier series analysis is eminently suitable for modeling strongly periodic data. Weather independent energy use such as lighting and equipment load in commercial buildings is strongly periodic and is thus appropriate for ...
Pre-Retrofit Lighting Study at the University of Texas at Arlington, Texas
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
As a part of the Energy Cost Reduction Measure (ECRM) retrofit program, funded by LoanSTAR, the U.T. Arlington site was granted a $2 million loan to implement an energy-saving lighting retrofit in 20 classroom buildings ...
Potential Operation and Maintenance (O&M) Savings in the John Sealy North Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
The LoanSTAR Monitoring and Analysis Group, Energy Systems Laboratory at Texas A&M University, was requested by University of Texas Medical Branch at Galveston to investigate O&M measures in their five LoanSTAR program ...
Analysis of Energy Conservation Options for USDOE Child Development Center
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
The Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features, including a photovoltaic system, solar hot water system, energy efficient lighting, ...
Using DOE Industrial Energy Audit Data for Utility Program Design
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1993-03)
The U.S. Department of Energy (DOE), Energy Analysis and Diagnostic Center Program has offered no-cost energy conservation audits to industrial plants since 1976. The EADC program has maintained a database of detailed plant ...
The Impact of Charge on Performance of an Air-to-Air Heat Pump for R22 and Three Binary Blends of Refrigerants 32 and 134A
(Texas A&M University, 1993)
Not available
Performance Characteristics of an Electrochemically Powered Turboprop: A Comparison with State of the Art Gas Turbines
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1993-03)
As we search for alternative fuels and energy efficient vehicles it is important to consider the role of electrochemical fuel cells in aircraft propulsion systems. This paper focuses on this issue with regards to small ...
Brayton Solvent Recovery Heat Pump Technology Update
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1993-03)
The Brayton cycle technology was developed to reduce the temperature of gas streams containing solvents in order to condense and recover them. While the use of turbo compressor/expander machinery in conjunction with an ...