Power Signatures as Characteristics of Commercial and Related Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
This paper proposes the use of "power signatures" as
an important concept for building energy analysis. Power signatures
are considered to contain "energy or power
characteristics" of a building. Developing relationships ...
Energy Use Analysis for the Federal Energy Management Program
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
Recent congressional legislation allows federal agencies new authorities to
contract for energy savings by sharing the
acquired savings with an energy service
company. As part of its charter to make
the federal government ...
Ground and Water Source Heat Pump Performance and Design for Southern Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
Ground and water source heat pump systems have
very attractive performance characteristics when
properly designed and installed. These systems
typically consist of a water-to-air or
water-to-water heat pump linked to a ...
Energy Efficiency Design Evaluation for the Texas Department of Corrections
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
A rapid, but comprehensive review of the
electrical, mechanical and thermal systems in the
maximum security prisons to be built in Amarillo and
Gatesville, TX recommended 10 measures for each
prison which offered annual ...
Rating of Mixed Split Residential Air Conditioners
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
A methodology is presented for rating the performance
of mixed, split residential air conditioners.
The method accounts for the impact on system
performance of the indoor evaporator, expansion
device and fan; three major ...
Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1988)
This study assesses the dehumidifying performance
of the high efficiency residential central air conditioners
(CAC) in hot/humid climates typified
by that of Houston and Galveston. The performance
study is based on such ...
Development of the GE Quiet Combustor and Other Design Changes to Benefit Air Quality
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
The attractiveness of gas turbines in cogeneration facilities and combined-cycle (Brayton-Rankine) power plants is linked to high specific work; power per unit mass flow. Manufacturers have, over the years, increased gas ...
Plantwide Energy Management for Hydrocarbon and Petrochemical Industry
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
Within the hydrocarbon and petrochemical industry the
generation and utilization of various forms of energy is a highly
complex and dynamic process. The process plant normally
generates steam and fuel in the form of ...
Emissions Resulting from the Full-Scale Cofiring of Pelletized Refuse-Derived Fuel and Coal
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
Full-scale cofiring tests of binder-enhanced pellets of densified, refuse-derived fuel (dRDF) and high-sulfur coal were conducted during June and July of 1987 in Boiler #5 at Argonne National Laboratory. These tests were ...
Experiences with On-Line STEAMPOP
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
Off-line utility system optimizers for
large process plants are now common place. However, the use of these optimizers
for operations optimization is usually limited
by the need for trained personnel to run these
programs ...