Field Performance of a Ground-Coupled Heat Pump in Abilene, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
A nominal 10.6 kW (3 ton), vertical-configuration
ground-coupled heat pump was
installed in Abilene, Texas in December 1989
and was monitored until May 1993 using a
remote data acquisition system. The unit was
installed ...
Calibration of Relative Humidity Transducers for use in the Texas LoanSTAR Program
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
In support of the Texas LoanSTAR Energy Conservation Program, the Texas A&M University Monitoring and Analysis Program (MAP) calibration facility has been performing relative humidity calibrations for transducers being ...
Metering and Calibration in LoanSTAR Buildings
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
End-use metering in commercial buildings often
requires installation of a large variety of transducers and data
loggers. The metering installation group in the LoanSTAR
monitoring program has the primary responsibility for ...
Instrumenting Buildings to Determine Retrofit Savings: Murphy's Law Strikes Again
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
Experiences with instrumentation, installation
and maintenance of building energy metering systems
are presented. The building energy metering was
installed in a variety of locations in programs handled
by the Energy Systems ...
Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners
(Texas A&M University (http://www.tamu.edu)Energy Systems Laboratory (http://esl.tamu.edu), 1998)
This paper presents results of a survey of the
literature and identifies the most common degraded
conditions associated with low-tonnage air
conditioners. Other laboratory studies as well as
marketed diagnostic systems ...
Assessment and Suggestions to Improve the Commercial Building Module of EIA-NEMS
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1996)
The National Energy Modeling System (NEMS) is a comprehensive, computer-based, energy-economy modeling system developed and maintained by the Department of Energy's Energy Information Administration (EIA). NEMS forecasts ...
Monitoring the Performance of a Residential Central Air Conditioner under Degraded Conditions on a Test Bench
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
This report presents the measured degradation in performance of a residential air conditioning
system operating under degraded conditions. Experiments were conducted using a R-22 threeton
split-type cooling system with ...
Texas LoanSTAR Monitoring and Analysis Program: Report to the Monitoring and Analysis Review Committee
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
Texas LoanSTAR Monitoring and Analysis Program: Report to the Monitoring and Analysis Review Committee, August 1991 (Volume I)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
The LoanSTAR program has now completed its second prototype year. This report is Volume I of a two volume set that documents the progress since the January 1991 MARC meeting. This first voume contains photocopies of the ...
Radiant Barrier Performance during the Heating Season
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
Results of winter experiments conducted in Central Texas are presented. The experiments were side-by-side tests using two identical 144 ft2 houses which responded similarly to weather variations prior to any retrofits. Two ...