Improved Analysis Methods for Retrofit Savings and Energy Accounting (ERAP #227)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1990)
This report summarizes progress through November, 1990 for ERAP project No. 227, "Improved Analysis Methods for Retrofit Savings and Energy Accounting." The major objectives of this project are to: (1) determine the energy ...
Potential Operation and Maintenance (O&M) Savings at the Dunbar Middle and Sims Elementary Schools
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential cost savings which may be
achieved by improving operational and maintenance (O&M) practices at Dunbar Middle
School and Sims Elementary School in the Fort Worth ...
A Comprehensive Review of the Tests Completed on the Flow Loop at the Energy Systems Laboratory (Draft)
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
In 1988 the Governor's Energy Office (GEO) of Texas received approval from the U.S.
Department of Energy to establish a $98.6 million state-wide retrofit demonstration
program, the LoanSTAR (Loan to Save Taxes and ...
Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1992)
As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent
two retrofits: a) an absorption chiller was changed to an electric vapor compression
chiller, and b) an EMCS system was installed after ...
Potential Operation and Maintenance (O&M) Savings at the State Capitol Complex
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential cost savings by improving
operations and maintenance (O&M) practices at eight buildings of the State Capitol
Complex, monitored by the LoanSTAR program. This ...
Potential Operation and Maintenance (O&M) Savings at Schools in the Ft. Worth Independent School District
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
As part of the Texas LoanSTAR program, 44 schools in the Fort Worth Independent
School District (FWISD) had lighting retrofits performed on there in late 1991. The
Energy Systems Laboratory of Texas A&M University is ...
Potential Operation and Maintenance (O&M) Savings in the Basic Science Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential energy savings due to optimizing the Heating, Ventilation and Air Conditioning (HVAC) operation schedule in the Basic Science Building at University of Texas ...
A Report on the Environmental Impact of the Texas LoanSTAR Program from May 1989 to September 1995
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1995)
The Texas LoanSTAR (Loans to Save Taxes and Resources) program was created by the state of Texas in 1989 to lend money for energy conserving improvements, or retrofits, in public buildings. As of September 1995 the LoanSTAR ...
Simulation of the Post-Retrofit Thermal Energy Use for the Perry-Castaneda Library Building with the Use of Simplified System Models
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1991)
Several state owned buildings with dual-duct constant volume (DDCV) systems are
being retrofitted with energy efficient variable air volume (VAV) systems as part of Texas
LoanSTAR Program. One method of determining the ...