Search
Now showing items 191-200 of 1233
An Independent Refiner's Approach - Practical Solutions To Complex Gear Problems.
(Texas A&M University. Turbomachinery Laboratories, 1990)
Numerous failures and near failures spanning the last quarter century have occurred on a 4000 hp, single induction, double helical speed increaser in hydrogen recycle service. A persistent and unexplainable wear pattern, ...
Specifying, Manufacturing, And Testing A Cryogenic Turboexpander Magnetic Bearing System.
(Texas A&M University. Turbomachinery Laboratories, 1991)
The state-of-the-art magnetic bearing system, as it exists today, has several unique characteristics which tend to make certain applications of this technology more favorable than others. One application which seems quite ...
Table of Contents for the Proceedings of the 19th Turbomachinery Symposium
(Texas A&M University. Turbomachinery Laboratories, 1990)
Effect of a 90° Elbow on the Accuracy of an Insertion Flowmeter, Results and Comparisons for 4 and 6 in. Diameter PVC Pipe
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Thermal energy consumption in buildings with
chilled or hot water distribution systems is often
monitored through the use of some type of flow
metering device. These flowmeters can be fixed types,
such as venturis or ...
Customer Cycling Program in the City of Weimar
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
The City of Weimar Conservation/Load
Management (CLM) Program demonstrates to other
small Public Power Systems that a small city electric
distribution system with 1,097 meters serving a
population of less than 2,500 can ...
Pre-Retrofit Lighting Study at the University of Texas at Arlington
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
In the summer of 1993 the University of Texas at Arlington Physical Plant Department submitted a request to the Energy Systems Lab to conduct a lighting study to determine the most cost-effective method of implementing ...
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Air static pressure must be maintained at a
certain level leaving the air-handing unit (AHU) to
force a suitable amount of air through the terminal
boxes. However, an excessive static pressure level is
often used due to ( ...
The Framework of an Optimization Model for the Thermal Design of Building Envelopes
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Careful long term decisions in the design and
operation of buildings can significantly improve the
thermal performance and thus reduce the
consumption of energy. The availability and ease of
use of today's computers can ...
Selecting Thermal Storage Systems for Schools
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1990)
Mesquite is a suburb located on
the east side of Dallas with a
population of approximately
120,000. The school district
covers over 60 square miles with a
student population of 25,000. The
34 schools consist of 25
elementary, ...
An Improved Multipyranometer Array for the Measurement of Direct and Diffuse Solar Radiation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
This paper describes an improved
multipyranometer array (MPA) for the continuous
remote measurement of direct and diffuse solar
radiation. The MPA described in this paper is an
improvement over previously published MPA ...