Non-Intrusive Electric Load Monitoring in Commercial Buildings
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
Increased interest in optimal control, energy scorekeeping and
fault detection for HVAC equipment in commercial buildings has
focused attention on instrumentation required to obtain the
desired data. In this paper we ...
Survey of Energy Use in Grocery Stores
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
This paper presents the results of an energy use survey assembled for 93 grocery stores in south Texas. All stores were of the same chain. Several conclusions were drawn. Total electricity consumption per square foot is ...
A Simplified Procedure for Sizing Vertical Ground Coupled Heat Pump Heat Exchangers for Residences in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
A simplified technique for the sizing of vertical
U-tube ground coupled heat pump (GCHP) heat
exchangers for Texas climates was developed
utilizing a transient simulation model of a ground
coupled heat pump and weather and ...
Cooling-Only Prism Analysis of Eleven College Station Homes and Interpretation of Building Physical Parameters
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
A cooling-only PRISM analysis has been
performed on eleven new residences in College
Station using electricity billing data over an entire
year. This study revealed that, provided one corrects
for effects such as vacation ...
Effect of Radiant Barrier Technology on Summer Attic Heat Load in South Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
The objective of the study was to experimentally
evaluate the performance of radiant barriers in
single-family occupied housing units in South
Texas. Ceiling heat fluxes, attic air temperatures,
indoor air temperatures, ...
Dehumidification Without Re-heat Using Face and Bypass Dampers
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Installations with chill water cooling, needing
constant air volume and dehumidification,
traditionally use a draw through air handling unit
with a cooling coil and a re-heat coil.
Dehumidification is achieved by overcooling ...
A Calibration Methodology for Retrofit Projects Using Short-Term Monitoring and Disaggregated Energy Use Data
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
This paper presents an improved methodology to
calibrate energy simulation models to better represent
the actual energy use breakdowns in existing buildings.
The goal of this methodology is to help architects
and engineers ...
Residential Air Conditioner Direct Load Control "Energy Partners Program"
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Demand side management
programs like Energy Partners
can provide an effective peak
reducing capability which
within a carefully designed
integrated resource plan can
help to ensure that the
system's load requirements are
met ...
Ventilation Air Preconditioning Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Increased outside ventilation air
requirements demand special attention to
how that air will be conditioned. In winter,
the incoming air may need preheating; in
summer. the mixed air may be too humid for
effective ...
Designing a Thermal Energy Storage Program for Electric Utilities
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
Electric utilities are looking at thermal
energy storage technology as a viable demand side
management (DSM) option. In order for this
DSM measure to be effective, it must be
incorporated into a workable, well-structured
utility ...