Search
Now showing items 71-80 of 174
Online Diagnostics Of Rotating Machinery.
(Texas A&M University. Turbomachinery Laboratories, 1988)
Has the industrial standardization of the IBM PC/ AT as a building block for dedicated instrument computer systems brought costs down to the point where sophisticated monitoring systems are not only possible, but make good ...
Nondestructive Testing of Turbomachinery Components
(Texas A&M University. Turbomachinery Laboratories, 1988)
Nondestructive evaluation is becoming increasingly important in determining the quality of materials and fabrications used in the manufacture and maintenance of rotating machinery. NDE has long been used as a tool for ...
An Analysis of Efficiency Improvements in Room Air Conditioner
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1988)
Energy Use and Design Options for Texas State Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1988)
In 1984, the Office of Governor in the State of Texas, working through
the Energy Efficiency Division of the Public Utility Commission, instituted
a program to reduce the energy costs in state owned buildings. One
facet ...
An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with Capillary Tube Expansion
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1988)
The effect of the improper charging on the performance
(capacity, EER, power consumption, SEER, and coefficient of
degradation) of a residential air conditioner during the
steady state (wet and dry coils) and cycling ...
Optimizing Control- A Survey
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
The major asumptions that underlay the application
of optimizing control and the properties of the methods are
presented based on the general problem of simultanuously
optimizing and controlling a plant. The separation ...
The Cost of Heat Exchanger Fouling in the U. S. Industries
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
Fouling of heat exchangers costs the
U.S. industries hundreds of millions of dollars every year in increased equipment costs, maintenance costs, energy losses and losses in production. The designer of heat exchangers ...
Natural Gas Procurement Challenges for a Project Financed Cogeneration Facility
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
A decision to project finance a 110
megawatt combined cycle cogeneration facility
in 1986 in place of conventional internal
financing greatly changed the way in which
natural gas was normally procured by
Union Carbide ...
Electronic Applications of High Temperature Superconductors
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
The possible uses of high temperature superconductors in
electronics applications are reviewed. There are applications for
which the high temperature operation of these novel materials is
a significant advantage; one ...
Texas Bulk Power Study-- An Overview
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1988-09)
In the 1980's, several significant changes
have evolved in markets for electric power in
Texas. Cogeneration, fuel market volatility,
electric system reliability, generation and
transmission facility construction ...