Browsing by Author "Reddy, T. A."
Now showing items 1-20 of 33
-
O'Neal, D. L.; Reddy, T. A.; Sucher, B. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1996)The National Energy Modeling System (NEMS) is a comprehensive, computer-based, energy-economy modeling system developed and maintained by the Department of Energy's Energy Information Administration (EIA). NEMS forecasts ...
-
Katipamula, S.; Reddy, T. A.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)An empirical or regression modeling approach is simple to develop and easy to use compared to use of detailed hourly simulations. Therefore, regression analysis has become a widely used tool in the determination of annual ...
-
Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
Griffith, L.; Reddy, T. A.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)A cooling-only PRISM analysis has been performed on eleven new residences in College Station using electricity billing data over an entire year. This study revealed that, provided one corrects for effects such as vacation ...
-
Saman, N. F.; Reddy, T. A.; Haberl, J. S.; Claridge, D. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1996)This report has been prepared for the United States Army Construction Engineering Research Laboratories (CERL) located at Champaign, IL. The report describes the work performed by the Energy Systems Laboratory (ESL) of ...
-
Reddy, T. A.; Elleson, J.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)
-
Reddy, T. A.; Elleson, J.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2000)This is the final report for ASHRAE Research Project 1004-RP: Determining Long-Term Performance of Cool Storage Systems from Short-Term Tests. This report presents the results of the development and application of the ...
-
Reddy, T. A.; Elleson, J.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1999)This is the Spring 1999 progress report on ASHRAE Research Project RP 1004: Determining Long-Term Performance of Cool Storage Systems from Short-Term Tests. This report presents an update concerning the work that has been ...
-
Haberl, J. S.; Claridge, D. E.; Reddy, T. A.; Elleson, J. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1997)This is the preliminary report contains the literature review and site selection recommendations for ASHRAE Research Project RP 1004 — "Determining Long-term Performance of Cool Storage Systems From Short-term Tests".
-
Reddy, T. A.; Elleson, J.; Haberl, J. S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1998)This preliminary report contains the literature review, a preliminary description of the methodologies that have been chosen for the project and final site selection recommendations for ASHRAE Research Project RP 1004 ~ ...
-
Reddy, T. A.; Saman, N. F.; Claridge, D. E.; Haberl, J. S.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1996)This report has been prepared for the United States Army Construction Engineering Research Laboratories (USACERL) located in Champaign, IL by the Energy Systems Laboratory (ESL) of Texas A&M University. The first phase of ...
-
Reddy, T. A.; Saman, N. F.; Claridge, D. E.; Haberl, J. S.; Turner, W. D.; Chalifoux, A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)The Fort Hood Army base in central Texas has more than 5,200 buildings and can be considered as typical of large Department of Defense Army bases in the continental United States. The annual utility bill of the base ...
-
Reddy, T. A.; Saman, N. F.; Claridge, D. E.; Haberl, J. S.; Turner, W. D.; Chalifoux, A. (Energy Systems Laboratory (http://esl.tamu.edu), 1996-04)The Fort Hood Army base in central Texas has more than 5,200 buildings and can be considered as typical of large Department of Defense Army bases in the continental United States. The annual utility bill of the base exceeds ...
-
Saman, N. F.; Reddy, T. A.; Haberl, J. S.; Claridge, D. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1995)This report has been prepared for the United States Army Construction Engineering Research Laboratories (CERL) located at Champaign, IL. The report describes the work performed by the Energy Systems Laboratory (ESL) of ...
-
Katipamula, S.; Reddy, T. A.; Claridge, D. E. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)In hot and humid climates, where summers are both warm and humid, the latent cooling can be a significant portion of the total cooling load (as much as 40%). Typically the monitored data only includes whole-building heating ...
-
Reddy, T. A.; Vaidya, S.; Griffith, L.; Bhattacharyya, S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)Severe capacity problems are experienced by electric utilities during hot summer afternoons. Several studies have found that, in large part, electric peak loads can be attributed to residential airconditioning use. This ...
-
Claridge, D. E.; Heffington, W. M.; O'Neal, D. L.; Turner, W. D.; Haberl, J. S.; Reddy, T. A. (2005-09-27)In 1988 the Governor's Energy Management Center of Texas received approval from the U.S. Department of Energy to establish a $98.6 million state-wide retrofit demonstration revolving loan program to fund energy-conserving ...
-
Wang, W.; Claridge, D. E.; Reddy, T. A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)The measured energy savings from retrofits in buildings is often determined as the difference between the energy consumption predicted by a baseline model and the measured energy consumption during the post retrofit ...
-
Reddy, T. A.; Kissock, J. K.; Katipamula, S.; Ruch, D. K.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)Development of methodologies to determine energy retrofit savings in commercial buildings (institutional buildings, schools, hospitals, offices, county and state buildings,...) has been the object of active research during ...