Show simple item record

dc.creatorBuchanan, Jennifer Leona
dc.date.accessioned2012-06-07T22:58:36Z
dc.date.available2012-06-07T22:58:36Z
dc.date.created2000
dc.date.issued2000
dc.identifier.urihttps://hdl.handle.net/1969.1/ETD-TAMU-2000-THESIS-B823
dc.descriptionDue to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item.en
dc.descriptionIncludes bibliographical references (leaves 70-74).en
dc.descriptionIssued also on microfiche from Lange Micrographics.en
dc.description.abstractLiquefaction is a major concern for bridge column foundations in earthquake prone regions. Although its effects are devastating to the structural integrity of foundations, there is little quantitative information to guide engineers in the design of bridge column pile foundations that may be subjected to liquefaction of the surrounding soil during a seismic event. In order to quantify the effect of liquefaction on the stiffness and damping provided by a pile foundation under the cyclic loading that occurs during a seismic event, a representative foundation often used in bridge design is modeled using linear finite elements. The case study foundation is a 3x10 pile group with thirty concrete piles that are each 15 m deep. The effectiveness of a common micro-pile retrofit is also examined through the use of the finite element model. Sixteen 30 m deep micro-piles are added to the perimeter of the 3x10 pile group and are connected to the original 3x10 pile foundation with an expanded pile cap. These slender piles are comprised of reinforced concrete partially encased with a steel pipe. Loading is applied to the finite element model at frequencies of 0, 2, 4, and 8 Hertz in three directions of translation and two directions of rotation. Liquefaction is simulated in the finite element model by decreasing the elastic modulus of various layers in the model to ten percent and one percent of their original value. The quantitative effects of different loading directions and frequencies are observed when both the retrofitted and non-retrofitted model are subjected to varying degrees of liquefaction at several different soil depths. The information obtained in these simulations is then used to develop stiffness and damping modification factors. This study shows that the effect of retrofitting and of liquefaction on the dynamic behavior of the pile group is highly dependent on load direction, load frequency, and liquefied layer location.en
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherTexas A&M University
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.subjectcivil engineering.en
dc.subjectMajor civil engineering.en
dc.titleEffect of liquefaction on the behavior of a retrofitted pile foundation subjected to cyclic loadingen
dc.typeThesisen
thesis.degree.disciplinecivil engineeringen
thesis.degree.nameM.S.en
thesis.degree.levelMastersen
dc.type.genrethesisen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.

Request Open Access