NOTE: This item is not available outside the Texas A&M University network. Texas A&M affiliated users who are off campus can access the item through NetID and password authentication or by using TAMU VPN. Non-affiliated individuals should request a copy through their local library's interlibrary loan service.
Performance of bolted wood connections using supplemental confining devices
dc.creator | Stromatt, Rebecca Faye | |
dc.date.accessioned | 2012-06-07T22:46:59Z | |
dc.date.available | 2012-06-07T22:46:59Z | |
dc.date.created | 1996 | |
dc.date.issued | 1996 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/ETD-TAMU-1996-THESIS-S77 | |
dc.description | Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item. | en |
dc.description | Includes bibliographical references. | en |
dc.description | Issued also on microfiche from Lange Micrographics. | en |
dc.description.abstract | In the aftermath of the 1994 Northridge Earthquake, extensive field investigations revealed damage in wood frame construction in the form of splitting the 2x4 or 2x6 dimension lumber sill plates along the line of anchor bolts which typically connect shear walls to the masonry or concrete foundation. This paper presents an experimental investigation on the performance of bolted wood connections at the yield and ultimate limit states during monotonic and incremental quasi-static reversed cyclic loading and suggests possible retrofit strategies for their improved seismic performance. Proposed retrofit strategies are based on providing confinement to the bolted wood member using metal reinforcing ;traps and reinforcing clamps to increase the deformation capability and energy dissipation capacity of the connection, while maintaining substantial levels of connection strength. Connection types included in the investigation are: (1) double shear wood-to-wood connections; and (2) single shear simulated sill plate-to-concrete foundation connections. | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | |
dc.publisher | Texas A&M University | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.subject | civil engineering | en |
dc.subject | Major civil engineering | en |
dc.title | Performance of bolted wood connections using supplemental confining devices | en |
dc.type | Thesis | en |
thesis.degree.discipline | civil engineering | en |
thesis.degree.name | M.S. | en |
thesis.degree.level | Masters | en |
dc.type.genre | thesis | en |
dc.type.material | text | en |
dc.format.digitalOrigin | reformatted digital | en |
Files in this item
This item appears in the following Collection(s)
-
Digitized Theses and Dissertations (1922–2004)
Texas A&M University Theses and Dissertations (1922–2004)
Request Open Access
This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.