NOTE: This item is not available outside the Texas A&M University network. Texas A&M affiliated users who are off campus can access the item through NetID and password authentication or by using TAMU VPN. Non-affiliated individuals should request a copy through their local library's interlibrary loan service.
Laser velocimetry study of the flow field in a centrifugal pump with a shrouded impeller
dc.creator | Moran, Michael Kevin | |
dc.date.accessioned | 2012-06-07T22:37:34Z | |
dc.date.available | 2012-06-07T22:37:34Z | |
dc.date.created | 1994 | |
dc.date.issued | 1994 | |
dc.identifier.uri | https://hdl.handle.net/1969.1/ETD-TAMU-1994-THESIS-M8294 | |
dc.description | Due to the character of the original source materials and the nature of batch digitization, quality control issues may be present in this document. Please report any quality issues you encounter to digital@library.tamu.edu, referencing the URI of the item. | en |
dc.description | Includes bibliographical references. | en |
dc.description.abstract | This study provides laser velocimetry measurements of the flow field within a centrifugal pump. The pump had a shrouded impeller of 254 mm diameter with five blades of backswept design. Measurements were made using a laser-two-focus (L2F) velocimetry system, both within the rotating impeller passages and in the pump volute. Both design operating conditions and off-design conditions were investigated. A comparison was made with a previous study, wherein measurements of the flow field were completed within the same pump, with an open face impeller. The absolute velocity, relative velocity, and turbulence kinetic energy levels were measured. The flow field within the impeller passages for the shrouded case was notably more uniform than for the unshrouded case. In addition, the turbulence kinetic energy within the passages was substantially lower. The efficiency of the shrouded pump was, however, lower than the unshrouded version. This was attributed primarily to losses due to leakage in the clearance region between the impeller shroud and the pump casing; a rather large passage was necessary to permit optical access. Velocimetry measurements were successfully made in the clearance region, and a leakage flow calculation was made. | en |
dc.format.medium | electronic | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | |
dc.publisher | Texas A&M University | |
dc.rights | This thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries in 2008. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use. | en |
dc.subject | mechanical engineering. | en |
dc.subject | Major mechanical engineering. | en |
dc.title | Laser velocimetry study of the flow field in a centrifugal pump with a shrouded impeller | en |
dc.type | Thesis | en |
thesis.degree.discipline | mechanical engineering | en |
thesis.degree.name | M.S. | en |
thesis.degree.level | Masters | en |
dc.type.genre | thesis | en |
dc.type.material | text | en |
dc.format.digitalOrigin | reformatted digital | en |
Files in this item
This item appears in the following Collection(s)
-
Digitized Theses and Dissertations (1922–2004)
Texas A&M University Theses and Dissertations (1922–2004)
Request Open Access
This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.