Show simple item record

dc.contributor.advisorHaupt, L. M.
dc.creatorKilmer, Robert Earl
dc.date.accessioned2020-08-20T19:43:41Z
dc.date.available2020-08-20T19:43:41Z
dc.date.issued1964
dc.identifier.urihttps://hdl.handle.net/1969.1/DISSERTATIONS-174021
dc.description.abstractA prime objective in a large electrical power network is that of scheduling the generation at various generating plants to supply the existing network loads and transmission losses while minimizing the total cost of generation and keeping the network voltages, power, and reactive voltamperes within practical operating limits. To achieve this objective, an optimum solution is obtained by modification of the generator power schedule, the magnitude of voltage held at generator and L-T-C busses, and the off-nominal turns ratio of the transformers instead of only rescheduling the generator powers as previous methods have done. The necessary condition for an optimum modification, which will minimize the total cost of generation and keep the network voltage, power, and reative volt-amperes within practical operating limits is established by using transformations of the fundamental bus voltage equations and the method of Lagrangian multipliers. The sufficient conditions for these equations were not proven, but the results obtained from the examples given show that a minimum is achieved within given engineering based constraints. The demonstration of the method was made on a newtwork used as a standard for literature on load flow analysis and on an operational power network. The method in its present form requires too much digital computer time to obtain a solution; therefore, it can not be considered for use in an automatic generator power dispatching system. It does, however, furnish valuable information which has not been available before for planning additions to a network and for determining the best operating procedure for a network.en
dc.format.extent62 leavesen
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectMajor electrical engineeringen
dc.subject.classification1964 Dissertation K48
dc.titleEconomic dispatch solution of an electric power network with optimum selection of generator bus voltages and transformer turns ratiosen
dc.typeThesisen
thesis.degree.disciplineElectrical Engineeringen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameDoctor of Philosophyen
thesis.degree.namePh. D. in Electrical Engineeringen
thesis.degree.levelDoctoralen
thesis.degree.levelDoctorialen
dc.contributor.committeeMemberDenison, John S.
dc.contributor.committeeMemberSims, Stillman A.
dc.type.genredissertationsen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen
dc.publisher.digitalTexas A&M University. Libraries
dc.identifier.oclc5713171


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.

Request Open Access