Show simple item record

dc.contributor.advisorO'Neal, Dennis L.
dc.creatorKim, Yongchan
dc.date.accessioned2024-02-09T20:43:15Z
dc.date.available2024-02-09T20:43:15Z
dc.date.issued1993
dc.identifier.urihttps://hdl.handle.net/1969.1/DISSERTATIONS-1474802
dc.descriptionVitaen
dc.descriptionMajor subject: Mechanical Engineeringen
dc.description.abstractHCFC-22 and HFC-134a were used with short tube orifices having length to diameter ratios ranging from 5 to 20 in a 9.53 mm (3/8 in.) refrigerant line to investigate both two-phase and subcooled liquid flow entering the short tubes. Flow temperature and pressure conditions were those typically found in air-conditioner and heat pump applications. Effects of each operating parameters and short tube geometry on the flow rate were discussed and included in the modeling. Both an analytical and semi-empirical model were developed. These models allowed better prediction of mass flow rate and investigation of transport properties inside the short tube. Generally, the flow trends for both refrigerants were similar even though mass flow rate range for HFC-134a was 30 % lower than that for HCFC-22 due to lower operating pressure conditions. Within normal heat pump or air-conditioner operating conditions, second-stage choking (choking at the outlet) was only approximated because the flow showed a small dependency on downstream pressure. For the conditions investigated, the mass flow rate was directly proportional to upstream pressure and upstream subcooling, but it showed only a small dependency on downstream pressure. For two-phase flow entering the short tube, the flow rate decreased with increasing quality. The mass flow rate was found to be dependent on cross sectional area, chamfer depth, and short tube length. For subcooled liquid entering the short tube, the delay of flashing, i.e. metastable liquid flow, was observed at the inlet section of the short tube. It was observed that the effects of oil concentration on mass flow rate varied as a function of short tube geometry and upstream subcooling or quality. The semi-empirical flow model and flow charts for both single and two-phase flow were developed by empirically correcting the modified single-phase orifice equation to satisfy the short tube orifice flow. For both HCFC-22 and HFC-134a, the maximum difference between measured data and the model's prediction was within [plus or minus]10%...en
dc.format.extentxx, 210 leavesen
dc.format.mediumelectronicen
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.rightsThis thesis was part of a retrospective digitization project authorized by the Texas A&M University Libraries. Copyright remains vested with the author(s). It is the user's responsibility to secure permission from the copyright holder(s) for re-use of the work beyond the provision of Fair Use.en
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectMajor mechanical engineeringen
dc.subject.classification1993 Dissertation K498
dc.subject.lcshTwo-phase flowen
dc.subject.lcshHeaten
dc.subject.lcshTransmissionen
dc.subject.lcshRefrigerantsen
dc.subject.lcshTestingen
dc.titleTwo-phase flow of HCFC-22 and HFC-134a through short tube orificesen
dc.typeThesisen
thesis.degree.disciplineMechanical Engineeringen
thesis.degree.grantorTexas A&M Universityen
thesis.degree.nameDoctor of Philosophyen
thesis.degree.namePh. Den
thesis.degree.levelDoctorialen
dc.contributor.committeeMemberAnand, N. K.
dc.contributor.committeeMemberParnell, Calvin B.
dc.contributor.committeeMemberPeterson, G. P.
dc.type.genredissertationsen
dc.type.materialtexten
dc.format.digitalOriginreformatted digitalen
dc.publisher.digitalTexas A&M University. Libraries
dc.identifier.oclc32294864


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

This item and its contents are restricted. If this is your thesis or dissertation, you can make it open-access. This will allow all visitors to view the contents of the thesis.

Request Open Access