Pre-Retrofit Lighting Study at the University of Texas at Arlington
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1994)
In the summer of 1993 the University of Texas at Arlington Physical Plant Department submitted a request to the Energy Systems Lab to conduct a lighting study to determine the most cost-effective method of implementing ...
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Air static pressure must be maintained at a
certain level leaving the air-handing unit (AHU) to
force a suitable amount of air through the terminal
boxes. However, an excessive static pressure level is
often used due to ( ...
An Advanced Economizer Controller for Dual Duct Air Handling Systems - with a Case Application
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Heating penalty is expected when economizers
are applied to dual-duct air handling systems.
The heating penalty can even be higher than the
cooling savings when the hot air flow is higher
than the cold air flow. To avoid ...
A Prediction of Energy Savings Resulting from Building Infiltration Control
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Heat transfer through building walls
consists of three main components:
conduction heat transfer, solar gain and
infiltration heat transfer. An interaction
among these three heat transfer
components alters the effective ...
The Measured Energy Impact of Infiltration in an Outdoor Test Cell
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
The energy consumption calculation of house envelopes assumes that conduction heat loss is independent on air infiltration heat loss, and that energy consumption is the sum of these losses. Anderlind [1985], Liu [1987], ...
Development of the Potential Energy Savings Estimation (PESE) Toolkit
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
This study has developed a prototype computer tool called the Potential Energy Savings Estimation (PESE) Toolkit. Baltazar’s methodology for potential energy savings estimation from EBCx/retrofit measures has been improved ...
Predicting Energy Usage in a Supermarket
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1989)
Very little is known about the energy using
systems in commercial and retail stores, which
consume 24.8% of the energy used by all commercial
buildings. This paper describes development of a
change-point regression model ...
Rehabilitating A Thermal Storage System Through Commissioning
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
A thermal storage system was installed in a
37,000 ft2 hospital in April 1992. The chiller
had to be operated every summer during peak
demand periods until the authors rehabilitated
system through building commissioning ...
Remote Fault Detection of Building HVAC System Using a Global Optimization Program
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
The energy efficiency of HVAC systems in
buildings often degrades with the passage of
time. Significant engineering time is normally
required to determine the cause(s) of the
degradation. This paper reports a preliminary ...
Hydraulic Modeling of Large District Cooling Systems for Master Planning Purposes
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)