Development of a Calibration Methodology for Code-compliant Simulation of a Case Study House in a Hot and Humid Climate
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
This paper describes a comparison of the results between a code-compliant DOE-2 simulation and monthly utility bills for a case study house in College Station, Texas. The comparison of the results is a preliminary step ...
Low Impact, Affordable, Low Income Houses for Mexico
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
This paper discusses an effort to develop low impact, affordable, low income houses for Mexico. Low impact houses are defined as houses with energy and water needs that are substantially reduced below levels corresponding ...
A Review of Ground Coupled Heat Pump Models Used in Whole-Building Computer Simulation Programs
(Energy Systems Laboratory (http://esl.tamu.edu), 2010-08)
Increasingly, building owners are turning to ground source heat pump (GSHP) systems to improve energy efficiency. Ground-coupled heat pump (GCHP) systems with a vertical closed ground loop heat exchanger are one of the ...
Survey of Energy Use in Grocery Stores
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
This paper presents the results of an energy use survey assembled for 93 grocery stores in south Texas. All stores were of the same chain. Several conclusions were drawn. Total electricity consumption per square foot is ...
Energy Savings Assessment for the Robert E. Johnson State Office Building in Austin, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
U.S. businesses and institutions spend an
estimated $175 billion per year for energy. Of that, the
fraction under performance contracts and energy
service agreements is currently growing, aided by
cheaper monitoring ...
NOx Emissions Reductions from Implementation of the 2000 IECC/IRC Conservation Code to Residential Construction in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
Four areas in Texas have been designated by
the United States Environmental Protection
Agency (EPA) as non-attainment areas because
ozone levels exceed the National Ambient Air
Quality Standard (NAAQS) maximum allowable
limits. ...
Program Overview: The Texas LoanSTAR Program; 1989-August 1997
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
The Texas LoanSTAR mans to Save Taxes
and Resources) program was conceived as a $98.6
million capital retrofit program for building energy
efficiency. The funding source is petroleum violation
escrow funds (PVE) from the ...
Methodology to Calculate NOx Emissions Reductions from the Implementation of the 2000 IECC/IRC Conservation Code in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
Four areas in Texas have been designated
by the United States Environmental Protection
Agency (EPA) as non-attainment areas because
ozone levels exceed the National Ambient Air
Quality Standard (NAAQS) maximum allowable
limits. ...
New MS-Windows-Based Educational Software for Teaching the Sunpath Diagram and Shading Mask Protractor
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
The well-known versions of the sunpath diagrams and
shading mask protractors that appear in the AIA's
Architectural Graphics Standards are based on the
equidistant projections and use a shading mask protractor
developed ...
Development of Baseline Monthly Utility Models for Fort Hood, Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
The Fort Hood Army base in central
Texas has more than 5,200 buildings and can be
considered as typical of large Department of
Defense Army bases in the continental United