Now showing items 1-20 of 45

    • Kim, S. B.; Woods, P. K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      This paper characterizes the variability of energy consumption due to a series of construction, occupant, and weather-related effects in duplex residences in College Station, Texas. In this paper, spline regression was ...
    • Sylvester, K. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Energy efficient glazing is necessary to reduce heat gains or losses that contribute to the high-energy use of buildings. However, high-rise commercial buildings that use energy efficient glazing are still consumptive. To ...
    • Bolander, J. N.; Murphy, W. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      Cogeneration feasibility studies were conducted for eleven state agencies of Texas. A net present value (NPV) analysis was used to evaluate candidate cogeneration systems and select the optimum system. CELCAP, an hour-by-hour ...
    • Schrecengost, R. C.; Lum, S. K.; Notman, J. R.; Sattler, D. R.; Heffington, W. M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      Sixty-two technical assistance (energy audit) reports by twelve different consulting firms representing fifteen independent school districts, nine hospitals, and five colleges have been reviewed to assess energy use ...
    • Ryan, B. J.; Griffith, J. W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      The selection of exterior elements for control of solar incidence has been a major concern for engineers, architects, and lighting designers. This concern relates to problems of thermal heat gain, direct glare and veiling ...
    • Soebarto, V. I.; Degelman, L. O. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      This paper presents an improved methodology to calibrate energy simulation models to better represent the actual energy use breakdowns in existing buildings. The goal of this methodology is to help architects and engineers ...
    • Claridge, D. E.; Schrock, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      The City of College Station, Texas adopted a new residential Energy Compliance Code in January, 1988. The code, which strengthens compliance requirements in several areas, has received broadly based support and acceptance ...
    • Katipamula, S.; O'Neal, D. L.; Farad, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      The energy use of the Travis Building at Austin, Texas was analyzed using the DOE 2.1B building energy simulation program. An analysis was made for the building as specified in the building plans and as operated by the ...
    • Heneghan, T.; Haberl, J. S.; Saman, N.; Bou-Saada, T. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      Building energy simulation programs have undergone an increase in use for evaluating energy consumption and energy conservation retrofits in buildings. Utilization of computer simulation programs for large facilities ...
    • Kim, B. S.; Degelman, L. O. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      It has long been recognized that evaporative cooling is an effective and logical substitute for mechanical cooling in hot-arid climates. This paper explores the application of evaporative coolers to the hot-humid climates ...
    • Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The lecture hall of the Richardson Petroleum Building at Texas A&M University is a large lecture hall, with a total floor area of approximately 2500 ft^2. The lecture hall was served by a constant air volume (CAV) air ...
    • Kim, K. S.; Boyer, L. L.; Degelman, L. O. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      In the first part of this study, daylighting levles in an actualy classroom are compared to scale model measurements and to computer program predictions. Secondly, the daylighting effects in the building atrium are examined ...
    • Russell, B. D.; Heller, R. P.; Perry, L. W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1984)
      Energy Management systems and particularly demand controllers are becoming more popular as commercial and light industrial operations attempt to reduce their electrical usage and demand. Numerous techniques are used ...
    • Kettleborough, C. F.; Ullah, M. R.; Waugaman, D. G. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      Desiccant cooling systems have been investigated extensively during the past decade as alternatives to electrically driven vapor compression systems because regeneration temperatures of the desiccant - about 160°F, can be ...
    • Landman, D. S.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      This paper describes an investigation of energy use in primary and secondary public schools to develop methods to identify high energy consuming schools, potential energy cost reduction measures (ECRMs) and operation and ...
    • Munger, B. K.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      This paper describes the development of simplified procedures for a multipyranometer array (MPA) for the continuous measurement of direct and diffuse solar radiation. The MPA described in this paper is an improvement over ...
    • Medina, M. A.; Turner, W. D.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      This paper presents simulated performance of insulation/radiant barrier systems under different Texas climates. A transient heat and mass transfer model which predicts thermal performance of residential attics (Medina, ...
    • Bryant, J. A.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      Thermal energy consumption in buildings with chilled or hot water distribution systems is often monitored through the use of some type of flow metering device. These flowmeters can be fixed types, such as venturis or ...
    • Ashley, R.; Garcia, O.; Medina, M. A.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      The objective of the study was to experimentally evaluate the performance of radiant barriers in single-family occupied housing units in South Texas. Ceiling heat fluxes, attic air temperatures, indoor air temperatures, ...
    • O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where ...