Now showing items 21-40 of 45

    • Soebarto, V. I.; Degelman, L. O. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      This study explored the effectiveness of selected external shading devices and glazing treatments used to minimize the total annual energy consumption in small office buildings in hot humid climates. The external shading ...
    • Degelman, L. O.; Boyer, L. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      In addition to the environment that atriums provide, the daylight admitted into such spaces can be utilized to displace part of the electric lighting load during the daylight periods. While within the atrium itself only ...
    • Oh, K. W.; Haberl, J. S.; Degelman, L. O. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The well-known versions of the sun-path diagrams and shading mask protractors that appear in the AIA's Architectural Graphics Standards (Ramsey and Sleeper 1994) are based on the equidistant projections and use a shading ...
    • Carrasco, A.; Pittard, R.; Kondepudi, S. N.; Somasundaram, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      Roof-Spray cooling systems are being extensively used to reduce the air-conditioning usage in industrial and commercial buildings. In buildings without air-conditioning, evaporative roof spray cooling systems help to reduce ...
    • Abdulmohsen, A.; Boyer, L. L.; Degelman, L. O. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      This paper presents part of an on-going research project in the College of Architecture at Texas A&M University. This research investigates how lightshelf daylighting delivery systems can manipulate sunlight and daylight ...
    • Katipamula, S.; O'Neal, D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      Experimental tests were conducted to measure the influence of radiant barriers and the effect of the radiant barrier location on attic heat transfer. All the tests were conducted in an attic simulator at a steady state. ...
    • Dobson, M.; O'Neal, D. L.; Aldred, W.; Margo, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      A nominal 10.6 kW (3 ton), vertical-configuration ground-coupled heat pump was installed in Abilene, Texas in December 1989 and was monitored until May 1993 using a remote data acquisition system. The unit was installed ...
    • Yborra, S. C.; Spears, J. W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes ...
    • Al-Homoud, M. S.; Degelman, L. O.; Boyer, L. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      Careful long term decisions in the design and operation of buildings can significantly improve the thermal performance and thus reduce the consumption of energy. The availability and ease of use of today's computers can ...
    • Katipamula, S.; Turner, W. D.; Murphy, W. E.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      An experimental study concerned with different modes of heal transfer in fibrous and cellulose insulating material is presented. A series of experiments were conducted using an attic simulator to determine the effects of ...
    • Zhu, Y.; Batten, T.; Turner, W. D.; Claridge, D. E.; Giebler, T.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, B.; Hirchak, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The energy costs of heating, ventilating and air conditioning usually represents a large portion of the utility bills for a medical facility. One large, modem medical center located in the hot and humid region of southern ...
    • Molinelli, J. F.; Boyer, L. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      Natural light (daylighting) in office buildings is often used to supplement or eliminate the artificial lighting otherwise required. When daylight can be effectively admitted and distributed, then energy is conserved, and ...
    • Molinelli, J. F.; Kim, K. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)
      The use of natural light (daylighting) in the atriums of office buildings is often done to supplement or eliminate the artificial lighting otherwise required. To the extent that the daylight can be effectively admitted and ...
    • Degelman, L. O. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes ...
    • Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain ...
    • Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)
      The Texas LoanSTAR program is an eight year, $98 million revolving loan program, funded by oil overcharge dollars, for energy conservation retrofits in Texas state, local government and school buildings. The program began ...
    • Houcek, J. K.; Claridge, D. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      In the summer of 1993 the University of Texas at Arlington Physical Plant Department submitted a request to the Energy Systems Lab to conduct a lighting study to determine the most cost-effective method of implementing ...
    • McWatters, K.; Claridge, D. E.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      Heat transfer through building walls consists of three main components: conduction heat transfer, solar gain and infiltration heat transfer. An interaction among these three heat transfer components alters the effective ...
    • Bryant, J. A.; Carlson, K. A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      Engineers at the Energy Systems Laboratory at Texas A&M University have completed short term energy metering studies at a complex of offices in northern Texas and several buildings on the Texas A&M University campus ...
    • Zhu, Y.; Batten, T.; Turner, W. D.; Claridge, D. E.; Liu, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)
      For many modem buildings, the chilled water loops and risers are equipped with variable speed pumping systems. How to quickly balance the loop or riser to satisfy the cooling requirement and reduce energy consumption is a ...