A Ten-Year, $7 Million Energy Initiative Marching on: Texas A&M University Campus Energy Systems CC
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The $35 million in measured savings for the ten-year, $7 million continuous commissioning (CC) program at the Texas A&M University (TAMU) makes the decision to continue easy. In today's energy environment and with the ...
Calculation of NOx Emission Reduction from Implementation of the 2000 IECC/IRC Conservation Code in Texas
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2003)
Four areas in Texas have been designated by the
United States Environmental Protection Agency
(EPA) as non-attainment areas because ozone
levels exceed the National Ambient Air Quality
Standard (NAAQS) maximum allowable ...
Texas Senate Bill 5 Legislation for Reducing Pollution in Non-Attainment and Affected Areas: An Overview of Legislative Responsibilities, Code Compliance Issues and Accomplishments
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
The 77th Texas Legislature, in 2001,
established Senate Bill 5, SB-5, which addressed
NOx emission reductions by establishing
programs to reduce vehicle emissions and
reductions due to energy efficiency and the use
of ...
Hydraulic Modeling of Large District Cooling Systems for Master Planning Purposes
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
An Introduction to Texas Senate Bill 5
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Four areas in Texas have been designated by the
U.S. Environmental Protection Agency (EPA) as
non-attainment areas because ozone levels
exceed the National Ambient Air Quality
Standards (NAAQS) maximum allowable ...
Results of CC Follow-Up in the G. Rollie White Building
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
An investigation into the increase of energy
consumption of G. Rollie White Coliseum was part
of the persistence project[1], which investigates the
savings in energy consumption of ten buildings that
were commissioned by ...
Improving Boiler Efficiency Modeling Based On Ambient Air Temperature
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
Optimum economic operation in a large
power plant can cut operating costs substantially.
Individual plant equipment should be operated
under conditions that are most favorable for
maximizing its efficiency. It is widely ...
The Business and Technical Case for Continuous Commissioning for Enhanced Building Operations - A Case Study: Alamo Community College District, San Antonio, Texas, USA
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2004)
This paper provides a business and technical case study for the Continuous Commissioning®(CC®) 1 process
developed by the Energy Systems Laboratory (ESL) at Texas A&M University System for building optimization.
The business ...
How Much Can a Campus Save on Utility Bills by Turning a 5-Workday Week Into a 4Workday Week
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2003)
The recent budget cuts campaign mandated
by the governor's office had all state agencies in
Texas looking for ways to reduce revenue
spending. One of the cost savings opportunities
perceived by many university officials ...
Improving Control of a Dual-Duct Single-Fan Variable Air Volume Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2003)
This paper discusses improved control strategies
for dual-duct single-fan variable air volume (VAV)
systems. Common control strategy for supply air
volume modulation is evaluated, and an improved air
volume control strategy ...