(Energy Systems Laboratory, 2019-08)
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)This report assesses several group measures that have been proposed by the City of Houston officials as part of the amendments to the 2009 IECC code - the Houston Amendments. The proposed group measures are for both ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1996)The National Energy Modeling System (NEMS) is a comprehensive, computer-based, energy-economy modeling system developed and maintained by the Department of Energy's Energy Information Administration (EIA). NEMS forecasts ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2012)This report is in response to the letter dated October 4, 2012, from the Energy and Green Advisory Board (EGAB) of the NCTCOG to the Energy Systems Laboratory. In this letter, the EGAB requested the Laboratory to perform ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 1997)At the request of the TAMU Power Plant, the ESL staff audited the 1995 Lone Star Gas Company invoices. Gas consumption is measured and the measured volume is converted to standard volume (at T=60 °F, P= 14.65 psia) to ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)The Automated Data Quality process development is an effort to automate the analysis and monitoring of the Energy Systems Lab's (ESL) polling and energy data process. Polling status refers to basic telecommunication line ...
-
(2002-12)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline analysis is also presented for the natural ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ESPC project at ...
-
(2007-09-21)This report presents electricity, natural gas and cooling baselines for the Thermal Plant, III Corp building, Darnall Hospital, Main Substation, West Substation, and North Substation. The baselines developed for this ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)An empirical or regression modeling approach is simple to develop and easy to use compared to use of detailed hourly simulations. Therefore, regression analysis has become a widely used tool in the determination of annual ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)As part of the LoanSTAR program, Victoria High School in Victoria, Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1992)DOE-2 yields hourly data on specific variables provided the user specifies the HOURLY-REPORT instruction. Analyzing the simulation results with hourly data gives a more detailed picture of how well the model is predicting ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)The University of Texas at San Antonio needs to expand their central chilled water distribution system as a result of planned additions to the campus. The current distribution system may be inadequate for the planned ...
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1985)
-
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1985)
-
(2008-04)A detailed study has been conducted of the performance of several innovative aspects of the Intelligent Workplace (IW) at Carnegie Mellon University, a low energy consumption building that uses radiant heating, cooling and ...
-
(Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2011)
-
(2007-07-10)This report presents a study of the application of the radiant barrier / duct models to the DOE-2.1e simulation program based on the previous methods (eQuest version 3.55 and EnergyGauge version 2.42) and the comparison ...
-
Comparative Testing of the ESL's Code-Compliant Simulation Model and the FSEC's EnergyGauge Software (2007-05)This report presents a study of the comparison of the results of the ESL’s code-compliant simulation model and the FSEC’s EnergyGauge (version 2.42). Sensitivity analyses were performed by varying window-to-wall ratio ...