Optimization of the Heating System Operation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
A new regulation method of the heating system is presented, which is based on the variation of outdoor temperature, to improve the economical efficiency and the timing regulation of the heating system. A function is put ...
Influence of Transfer Efficiency of the Outdoor Pipe Network and Boiler Operating Efficiency on the Building Heat Consumption Index
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
This paper analyzes the influence of transfer efficiency of the outdoor pipe network and operating efficiency of the boiler on the building heat consumption index, on the premise of saving up to 65 percent energy in different ...
Research on Cool Storage Time of a Phase Change Wallboard Room in the Summer
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Through testing and analysis of the parameters of the indoor thermal property in a phase change wallboard room and an ordinary room, the effects of using phase change wallboards on indoor temperature in summer and with air ...
Experiment on TiO2/AC Photocatalysis Technique to Eliminate Toluene in Air Conditioning Systems
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
The aims of the paper is to enhance indoor air quality, improve occupant comfort, increase the effectiveness of those who are studying and researching new purifying techniques, and use a TIO2/AC photocatalytic purifying ...
Determination of the Acceptable Room Temperature Range for Local Cooling
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
Determination of the acceptable room temperature range is a key problem in satisfactory design of local cooling for energy savings. At the room temperatures ranging from neutral to warm, three sensitive body parts-the face, ...
The Volatility and the Thermal Storage Performance of Binary Polyalcohol Systems Used in the Wall
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2006)
In this paper, the volatility of binary systems, consisting of neopentylglycol(NPG), pentaerythritol(PE) and trihytdroxy methyl-aminomethane(TAM) with different components, was studied experimentally. In the solid -solid ...
A Methodology to Pre-Screen Commercial Buildings for Potential Energy Savings Using Limited Information
(Texas A&M University, 2006-04-12)
Typical energy audits are sufficiently expensive and time-consuming that many
owners and managers of buildings are not willing to invest the time and money required
for a full audit. This dissertation provides a methodology ...
An Analysis of Maximum Residential Energy-Efficiency in Hot and Humid Climates
(Texas A&M University, 2006-04-12)
Energy-efficient building design involves minimizing the energy use and optimizing the
performance of individual systems and components of the building. The benefits of energyefficient
design, in the residential sector, ...
Analysis of Improved Fenestration for Code-Compliant Residential Buildings in Hot and Humid Climates
(Texas A&M University, 2006-10-30)
This thesis presents an analysis of energy efficient residential windows in hot and humid climates.
To accomplish this analysis, the use of accurate simulation tools such as DOE-2.1e is required, which