Potential Operation and Maintenance (O&M) Savings in the Basic Science Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report presents the results of a study of the potential energy savings due to optimizing the Heating, Ventilation and Air Conditioning (HVAC) operation schedule in the Basic Science Building at University of Texas ...
Summary of UTMB O&M Project: Energy Conservation Potential in Five Buildings
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
This report is a summary of five reports (references 1 to 5) which provided detailed
descriptions of an O&M investigation of the following five buildings on the UTMB
campus: 1) John Sealy North Building(JSN); 2) Clinical ...
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Air static pressure must be maintained at a
certain level leaving the air-handing unit (AHU) to
force a suitable amount of air through the terminal
boxes. However, an excessive static pressure level is
often used due to ( ...
An Advanced Economizer Controller for Dual Duct Air Handling Systems - with a Case Application
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Heating penalty is expected when economizers
are applied to dual-duct air handling systems.
The heating penalty can even be higher than the
cooling savings when the hot air flow is higher
than the cold air flow. To avoid ...
A Prediction of Energy Savings Resulting from Building Infiltration Control
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1996)
Heat transfer through building walls
consists of three main components:
conduction heat transfer, solar gain and
infiltration heat transfer. An interaction
among these three heat transfer
components alters the effective ...
The Measured Energy Impact of Infiltration in an Outdoor Test Cell
(Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
The energy consumption calculation of house envelopes assumes that conduction heat loss is independent on air infiltration heat loss, and that energy consumption is the sum of these losses. Anderlind [1985], Liu [1987], ...
Preliminary Study of O&M Opportunities at the University of Texas Medical Branch at Galveston, Submitted to The Energy Management and Operations Department at UTMB Galveston
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1994)
At the request of the Energy Management and Operations Department at the University of Texas Medical Branch at Galveston, the Energy Systems Laboratory at the Texas A&M University performed the preliminary study of O&M ...
Potential Operation and Maintenance (O&M) Savings in the John Sealy North Building at UTMB
(Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M UniversityDepartment of Mechanical Engineering, Texas A&M University, 1993)
The LoanSTAR Monitoring and Analysis Group, Energy Systems Laboratory at Texas A&M University, was requested by University of Texas Medical Branch at Galveston to investigate O&M measures in their five LoanSTAR program ...
Rehabilitating A Thermal Storage System Through Commissioning
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 1998)
A thermal storage system was installed in a
37,000 ft2 hospital in April 1992. The chiller
had to be operated every summer during peak
demand periods until the authors rehabilitated
system through building commissioning ...
Terminal Box Airflow Reset: An Effective Operation and Control Strategy for Comfort Improvement and Energy Conservation
(Energy Systems Laboratory (http://esl.tamu.edu)Texas A&M University (http://www.tamu.edu), 2002)
A new terminal box operation and control
strategy, airflow reset, is developed to improve
building comfort and energy efficiency during
unoccupied and lightly occupied hours. The airflow
reset lowers the minimum airflow ...